Chimney Installation
Termination Cap
Additional
support for
tall chimneys
Storm Collar
Maintain minimum
clearances to
combustibles as
specified
Chimney must extend
beyond combustible
roof structure
Maintain minimum
height of chimney
above roof
Install roof flashing
according to minimum
requirements
Offsets/returns
may not exceed
30° from vertical
Support straps for offsets/
returns must be secured
to adequate framing
Ceiling firestops
are required where
chimney passes
through ceiling or
floor
Attic Shield is
required where chimney
passes through attic
Figure 6.1 Typical Chimney System - Guidelines for Chimney System Installation
NOTICE:
Chimney performance may vary.
• Trees, buildings, roof lines and wind conditions affect performance.
• Chimney height may need adjustment if smoking or overdraft occurs.
A. Typical Chimney System
The SL300 series chimney (UL127 approved for use with this fireplace) is shipped with wrap around
warning labels installed. These labels may be removed from the sections of chimney exposed above
the roofline.