Figure 2.2 Fireplace Locations
NOTICE:
• Illustrations and photos reflect typical installations and
are FOR DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation/appearance may vary due to individual
design preference.
• Hearth & Home Technologies reserves the right to alter
its products.
NOTICE:
In addition to these framing dimensions, also
reference the following section:
• Clearances (Section 3).
NOTICE:
A minimum 1 in. air clearance at the back and a
minimum 1½ in. air clearance to the sides of the
fireplace assembly must be maintained.
Chimney sections at any level require a 2 in. mini-
mum air space clearance between the framing and
chimney sections.
B. Design and Installation Considerations
NOTICE:
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
1. Selecting Fireplace Locations
This fireplace may be used as a room divider, installed
along a wall, across a corner or used in an exterior chase.
See Figure 2.2.
Locating the fireplace in a basement, near frequently
opened doors, central heat outlets or returns, or other loca-
tions of considerable air movement can affect the perfor
-
mance.
Outside air must be used for combustion. The PIONEER
III comes equipped with an outside air inlet to feed com-
bustion air from outside the home, along with an outside air
termination cap; the metal duct is required but not supplied.
Consideration should be given to these factors before de
-
ciding on a location.
24-1/2*
[622]
51 [1295]
16 [406]
51 [1295]
[1562]
16 [406]
24-1/2*
[622]
24-1/2*
[622]
51
[1295]
16
[406]
48 [1219]
103
[2616]
51
[1295]
73 [1854]
51-1/2
[1308]
27-1/2
[699]
27-1/2
[699]
Across a corner
In an exterior chase
As a divider
Along a wall
*If interior of chase will be
drywalled, add the thickness
to this measurement.
Faceplate to sidewall 16 inches
61-1/2
[1562]
61-1/2
[1562]
61-1/2
7
Quadra-Fire • PIONEER - III • 4182-901 Installation Manual • Rev C • 07/19