R
September 24, 2015
7014-188L
Page 39
1200-I Pellet Insert
Ash Build Up in Firebox
Pellets Back Up
In Feed Tube
Firepot Overfills
Tall, Lazy Flame, Orange in Color
Incorrect
Correct Flame Size, Yellow/White in Color
Correct
Figure 39.3
Figure 39.4
Figure 39.5
Fire Risk.
WARNING
• High ash fuels, or lack of maintenance, can
cause the firepot to overfill. Follow proper
shutdown procedure if ash buildup exceeds
half way point in firepot.
• Failure to do so could result in smoking,
sooting and possible hopper fires.
D. High Ash Fuel Content Maintenance
• Frequency:
When the ash build-up exceeds more
than half way up the fi repot.
• By:
Homeowner
Poor quality pellet fuel, or lack of maintenance, can create
conditions that make the fi repot fi ll quickly with ashes and
clinkers.
This condition makes the appliance susceptible to overfi lling
the fi repot with pellets which may result in smoking, sooting
and possible hopper fi res.
Figure 39.3
shows an example
where the fi repot overfi lls, pellets back up into the feed tube
and ash has accumulated in the fi rebox.
An ineffi cient and non-economical method of burning of fuel
caused by poor quality pellet fuel
is shown in
Figure 39.4
.
The correct fl ame size when good quality, premium pellet
fuel is burned is shown in
Figure 39.5
.
If the ash buildup exceeds the half way point in the fi repot
IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.
19. Clean Firebox Exhaust Exits & Exhaust Blower
1. There are 2 exhaust exits at the back of the fi rebox on the
left and right side.
Figure 39.1
.
2. Using a Phllips head screwdriver remove the screws and
set aside the access covers.
3. Vacuum the 2 exhaust exits thoroughly.
4. Clean the exhaust blower blades while the access cover
on the left side is still removed.
Figure 39.2.
Clean-Out Door
Exhaust Blower
Vent Pipe Adapter
Figure 39.1
Exhaust
Blower
Convection
Blower
Hinged Access Door
Clean-Out
Door
Vent Pipe
Adapter
Firepot
Cleaning Rod
Figure 39.2
Summary of Contents for PELLET INSERT CB1200MI-MBK
Page 52: ...Page 52 7014 188L September 24 2015 R 1200 I Pellet Insert F Warranty Policy ...
Page 53: ...R September 24 2015 7014 188L Page 53 1200 I Pellet Insert ...
Page 54: ...Page 54 7014 188L September 24 2015 R 1200 I Pellet Insert ...
Page 55: ...R September 24 2015 7014 188L Page 55 1200 I Pellet Insert ...