R
September 24, 2015
7014-188L
Page 31
1200-I Pellet Insert
H. Frequently Asked Questions
ISSUES
SOLUTIONS
1. Metallic noise.
1. Noise is caused by metal expanding and contracting as
it heats up and cools down, similar to the sound pro-
duced by a furnace or heating duct. This noise does not
affect the operation or longevity of your appliance.
2. Ash buildup on glass.
2. This is normal. Clean the glass.
3. Glass has turned dirty.
3. Excessive build up of ash. The lower burn settings will
produce more ash, the higher burn settings produce
less. The more it burns on low the more frequent clean-
ing of the glass is required.
4. Fire has tall fl ames with black tails and is lazy.
4. The feed rate needs to be reduced or the fi repot needs
cleaning. Heat exchanger or exhaust blower needs
cleaning.
5. Smokey start-up or puffs of smoke from the airwash. 5. Either the fi repot is dirty or there is too much fuel at
start-up and not enough air. Close down feed rate 1/4
inch (6mm) at a time until this no longer happens.
6. Large
fl ame at start-up.
6. This is normal. Flame will settle down once the fi re is
established.
Odors and vapors released during initial operation.
• Curing of high temperature paint.
• Open windows for air circulation.
Odors may be irritating to sensitive individuals.
CAUTION
Summary of Contents for PELLET INSERT CB1200MI-MBK
Page 52: ...Page 52 7014 188L September 24 2015 R 1200 I Pellet Insert F Warranty Policy ...
Page 53: ...R September 24 2015 7014 188L Page 53 1200 I Pellet Insert ...
Page 54: ...Page 54 7014 188L September 24 2015 R 1200 I Pellet Insert ...
Page 55: ...R September 24 2015 7014 188L Page 55 1200 I Pellet Insert ...