![Quadra-Fire CLASSIC BAY 1200 Owner'S Manual Download Page 13](http://html2.mh-extra.com/html/quadra-fire/classic-bay-1200/classic-bay-1200_owners-manual_3394666013.webp)
13
7027-802C
June 4, 2019
CB1200 Free Standing
N. Thermostat Controls
TEMPERATURE (HEAT / OFF) SWITCH:
Set this switch to HEAT to control your appliance. The
OFF
position will disable the appliance.
SET (MULTI- FUNCTION) SLIDE SWITCH:
This provides easy access to common settings, and should
always remain in RUN unless items are being adjusted.
Figure 13.1
NOTE:
When thermostat is set to “Manual” non-
programmable mode, all positions of the SET
slide switch will act like RUN.
UP / DOWN BUTTONS:
The UP and
DOWN buttons are used to control the set
temperature, or adjust any other on-screen items. An items
flashing, is the item currently being adjusted.
HOLD BUTTON:
This button activates and deactivates the manual
Temperature
HOLD feature, which maintains a fixed set
temperature indefinitely without following a program routine.
COPY BUTTON:
This is used to copy temperature program items from one
day to the next. Also used to access the menu setup.
NEXT BUTTON:
This is used when setting items such as software options,
and temperature programs when they are flashing on the
screen. Pressing the
NEXT button will cycle through which
item is flashing.
O. Thermostat Setup Options
ITEM #01 (CLK = CLOCK FORMAT):
•
12Hr, default:
This displays the clock times using
standard AM and PM values.
•
24Hr:
This displays the clock times using the military-
time format (example 22:00 hours, without using
AM or PM).
ITEM #02 (TMP = TEMPERATURE SCALE):
•
F, default:
Shows all temperature values in Fahrenheit.
•
C:
Shows all temperature values Celsius.
ITEM #03 (PROGRAMMING STYLE):
•
7 Day, default:
This style uses a separate program
routine for each of the 7 days in the week.
•
5/2 Day:
This style uses a weekday program routine
for Monday, Tuesday, Wednesday, Thursday, Friday,
and a separate weekend program routine for Saturday
and Sunday.
•
Manual Non-Programmable:
In this setting, there are
no program routines for the thermostat to follow and
the temperature control will be set only by the UP and
DOWN buttons on the front panel.
ITEM #04 (PERD = EVENT OR PERIOD QUANTITY):
•
4P, default:
Thermostat uses four Events per day
(called
MORN, DAY, EVE
, and NITE).
•
2P:
The thermostat uses two Events per day (called
DAY and NITE).
NOTE:
Event or Period Quantity feature is not accessible
during Manual Non-Programmable mode.
ITEM #07 (DLAY = DELAY TIME):
•
5, default: Thermostat waits 5 minutes before turning
the system back on after it was last run. This internal
delay prevents the appliance from turning on too
quickly after shutting down. The 5 minute setting is fine
for most applications.
•
2: Same operation as above but reduced to 2 minutes
between state changes.
NOTE
: This delay does not happen when the thermostat
is manually turned up and down.
Setup options for how the thermostat will function are
performed using a menu on the display screen.
TO ACCESS THE SETUP MENU:
Move the System Mode Switch into the OFF position,
and then hold down the COPY button for approximately 5
seconds until the screen changes. The menu will always
start with item #01, and is advanced to each following item
by a single press of the NEXT button. The options for each
item are changed using the UP or
DOWN buttons.
ITEM #08 (TEMPERATURE DIFFERENTIAL):
•
The thermostat works by turning your heating system
on and off whenever the room temperature varies from
the desired set-point temperature.
•
Use the UP/DOWN buttons to change the number
value between 1 and 9. Generally your system
should cycle on about 3 to 6 times per hour. A smaller
differential number makes the system cycle more
frequently, so the room temperature is more precise
and constant. A larger differential number will make the
system remain on for a longer duration each time and
decreases the number of cycles per hour.
• Default is set to 4.