4100 Insert ACC

F. Install Checklist

ATTENTION INSTALLER:

Follow this Standard Work Checklist

This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this installation manual.

Customer: 

Date Installed: 

Lot / Address: 

Location of Appliance: 

Installer: 

Dealer / Distributor Phone #: 

Serial #: 

Model: 

WARNING! Risk of Fire or Explosion!

 

Failure to install appliance according to these instructions can lead to a fire or explosion.

Appliance Install

Verified clearances to combustibles.

Appliance is leveled and connector is secured to appliance.

Hearth extension size/height decided.

Outside air kit installed.

Floor protection requirements have been met.

If appliance is connected to a masonry chimney, it should be cleaned and

inspected by a professional. If installed to a factory built metal chimney, the 

chimney must be installed according to the manufacturer’s instructions and 

clearances.

Chimney

Chimney configuration complies with diagrams.

Chimney installed, locked and secured in place with proper clearance.

Chimney meets recommended height requirements (14-16 feet).

Roof flashing installed and sealed.

Terminations installed and sealed.

Clearances

Combustible materials not installed in non-combustible areas.

Verified all clearances meet installation manual requirements.

Mantels and wall projections comply with installation manual requirements.

Protective hearth strips and hearth extension installed per manual requirements.

Appliance Setup

All packaging and protective materials removed.

Firebrick, baffle and ceramic blanket installed correctly.

All labels have been removed from the door.

All packaging materials are removed from inside/under the appliance.

Manual bag and all of its contents are removed from inside/under the appliance 

and given to the party responsible for use and operation.

Hearth & Home Technologies recommends the following:

•     Photographing the installation and copying this checklist for your file.

•     That this checklist remain visible at all times on the appliance until the installation is complete.

Comments:  Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed:

Comments communicated to party responsible ____________________________ by _____________________ on ___________

(Builder / Gen. Contractor)

(Installer)

(Date)

_________________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

________________________________________________________________________

___________________________________________________________________________________

___________________________________________________________________

___________________________________________________________________________________

____________________________________________________________________________________

YES IF NO, WHY?

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

______________________________________

Summary of Contents for 41I-ACC-BK

Page 1: ...nch translation of this manual please contact your dealer or visit www quadrafire com Pour obtenir une traduction fran aise de ce manuel s il vous pla t contacter votre revendeur ou visitez www quadra...

Page 2: ...ney 15 J Metal Heat Circulating Masonry 16 K Prefabricated Metal Chimney 16 L Ovalizing Round Stainless Steel Liners 17 M Altering The Fireplace 17 N Zero Clearance Fireplace 17 5 Appliance Set Up 18...

Page 3: ...ighted average HHV efficiency using Douglas Fir dimensional lumber and data collected during EPA emissions test A range of BTU outputs based on EPA Default Efficiency and the burn rates from the low a...

Page 4: ...ng appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a fire hazard WARNING Fire Ris...

Page 5: ...draft should be approximately 10 inch W C Measure the W C at 6 inches 152mm above the top of the appliance after one hour of operation at each burn setting B Draft Check building codes prior to instal...

Page 6: ...2 3 4 in length 6 or 8 self drilling screws Fire Risk Inspect appliance and components for damage Damaged parts may impair safe operation Do NOT install damaged components Do NOT install incomplete c...

Page 7: ...appliance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this c...

Page 8: ...nd 43 1092 31 787 12 1 2 318 9 5 8 244 2 1 2 64 31 787 45 1143 51 1295 34 864 30 762 24 610 16 1 4 413 10 5 8 270 7 178 Figure 8 6 Front View with Large Cast Trim Steel Surround SP 41I CM LRG and 811...

Page 9: ...Figure 9 1 Side View with Steel Surround 5 127 4 1 8 105 15 20 7 8 530 21 1 2 546 21 1 8 537 9 1 8 232 11 3 8 289 Figure 9 2 Side View of Steel Surround with Optional 15 Degree Adapter DV 6DLR E15ADS...

Page 10: ...teel Surround 30 1 4 768 C Back Width 24 1 4 616 D Depth Steel Surround 16 1 2 419 Depth Cast Trim Steel Surround 16 1 2 419 B Clearances to Combustibles United States and Canada UL and ULC NOTE Minim...

Page 11: ...this for k value The HIGHER the R factor means less heat is being conducted through the non combustible material to the combustible material beneath it The R value of a material must be equal or larg...

Page 12: ...y should Install through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof Th...

Page 13: ...there are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 13 1 13 2 Must h...

Page 14: ...configuration the greater the likelihood it may affect performance Chimney height may need to be increased by 2 3 per each 1000 feet above sea level It is not recommended to use offsets or elbows at...

Page 15: ...nimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Off...

Page 16: ...with Non Combustible Material Minimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert Listing Combustible Floor Airtight Insulated Clean Out Stainless Steel Chi...

Page 17: ...Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits Inspect the existing fireplace and chimney for any dam...

Page 18: ...e 4 inch flex 4 After sliding can into fireplace feed flex into cut opening to obtain outside combustion air 5 Level outer can and install appliance 6 Remove 4 bolts from both sides of the blower hous...

Page 19: ...stic Figure 19 1 2 Attach gasket to bottom side of flue collar with a thin coat of silicone C Leveling Legs 1 Remove the 2 screws already installed on each leg 2 Move legs to the desired height 3 Re i...

Page 20: ...ng and blower assembly in reverse order F Blower Cord Installation on Left Side The blower cord is shipped on the right side of the appliance You may relocate the cord so it is on the left side 5 32 A...

Page 21: ...t metal shears cut trim along the marked edge The cut edge fits under lip of top trim so it allows for some variance in your straight edge 5 The double sided tape that holds front and side trims to sc...

Page 22: ...84 HUD requirements for outside combustion air supply to the fireplace fire chamber and the chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be us...

Page 23: ...23 January 10 2020 7045 910I 4100 Insert ACC 7 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service...

Page 24: ...24 January 10 2020 7045 910I 4100 Insert ACC Date of Service Performed By Description of Service...

Page 25: ...25 January 10 2020 7045 910I 4100 Insert ACC B Accessory List...

Page 26: ...and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this applianc...

Reviews: