10
January 10, 2020
7045-910I
4100 Insert ACC
SIDE TRIM
SIDE W
ALL
TOP TRIM
22-5/8 in
(575mm)
32-1/8 in
(816mm)
HEARTH
EXTENSION
USA 18-1/8 in (460mm)
CANADA
22-1/8 in (562mm)
42-1/8 in
(1070mm)
FIREPLA
CE FR
ONT SURF
ACE
HEARTH EXTENSION
(See next page for thermal protection
requirements)
MANTEL
44-1/8 in
1121mm
44-1/8 in
1121mm
12in max
12in max
USA 23-1/8 in (587mm)
CANADA 25-1/8 in (638mm)
USA 23-1/8 in (587mm)
CANADA 25-1/8 in (638mm)
C
D
A
B
Minimum Opening
Dimensions
Inches
Millimeters
A
Height
21-3/4
552
B
Front Width (Steel
Surround)
30-1/4
768
Front Width (Cast Trim
Steel Surround)
30-1/4
768
C
Back Width
24-1/4
616
D
Depth (Steel Surround)
16-1/2
419
Depth (Cast Trim Steel
Surround)
16-1/2
419
B. Clearances to Combustibles
United States and Canada (UL and ULC)
NOTE:
Minimum opening dimensions include a 1/4” (6mm)
clearance around unit.
NOTE:
If trim measurement is over 3/4 in (19mm) in depth
use mantle or side clearance to combustibles.
In Canada a full length 6 inch (152mm) S635 flue liner required as per ULC S628.
In USA a minimum 5 ft length (1.82m), 6 inch (152mm) diameter flue liner is required as per UL 1482.
NOTE:
Clearances may only be reduced by means
approved by the regulatory authority having
jurisdiction
Fire Risk.
•
Comply with all minimum clearances to
combustibles as specified.
•
Failure to comply may cause house fire.
WARNING