SET RIGHT LIMIT
To set another site’s position. Set it in the same way as
SET
LEFT LIMIT
.
DEFAULT SPEED-
Allows to set the scanning speed (camera movement speed).
Values range from
001 to 255
, the greater number, the higher speed. Pan right to
select, tilt up or down to change value.
RUN-
To start the current AUTO SCAN (001~004).
DELETE-
Deletes the current Auto Scan.
BACK-
Returns
Back to upper menu level.
3.8.5
SET ZONE
Main Menu -> AUTO RUNNING -> SET ZONE
A Zone is an area between two parallel points. The user can set a Zone and scan it
automatically.
The
SET ZONE
function is similar to the
AUTO SCAN
except that the user can
assign a title for a
ZONE
. (For example: Danger area). Whenever the camera
moves into the zone, the title will display on the screen to alert the operator.
Note:
The dome scans horizontally only. The User can set up to 8 zones in the
QT-220EX.
ZONE No.
Display the current zone number. Values are
001~008
. Pan right then
tilt up or down to select other zone.
TITLE:
To set the zone title. The following editing window will appear when this
menu item is selected: