background image

Hardware Description (continued)

Rear Panel

Amplifier DataPorts:

 Each DataPort provides two channels of audio from the DCM to the QSC amplifier input, as well as current 

and voltage monitoring of the amp’s loudspeaker outputs. Remote power on/standby control of the amplifier is also provided, allow-
ing the DCM to act as a master system power controller. 

Use only QSC DataPort cables. Custom-length DataPort cables with individually shielded-pair construction are available from QSC’s 
Technical Services Group. Stock lengths include 1, 2, 3, 4, 5, 6, 10, and 20 feet and are designated DPC-x (where “x” is the length in 
feet).

The maximum output configuration of the DCM 10/10D is a 6 ch / 2-way. The maximum output configuration of the DCM 30/30D is 
an 8 ch / 4-way. In addition, many parallel outputs are provided for additional flexibility.

The rear panel labelling on the DCM has all of the information required by an audio installer. When starting, write down the EXACT 
LOUDSPEAKER CONFIGURATION (for example, 8 channel, tri-amp with 2 surrounds and 4 subs). Now you can follow the rear panel 
text which shows both channel position (L or C or R, etc) and the frequency output (LO, MID, HI, etc). Connect the L-LO output to the 
correct amplifier driving the left positional loudspeaker’s low frequency transducer, and L-HI to the amplifier driving the same loud-
speaker’s high frequency transducer, etc.

DCM 30 DataPort Illustration:

WARNING: Incorrect frequency connections can damage transducers. Physically verify proper connections 
AND listen to each individual transducer at very low volume before applying full audio power.

INPUT SELECT Switch

: Use this switch to select the input source of the DCM. In the 

ANALOG 

position, input is from 

the 

MAIN ANALOG INPUT 

( and the 

SURROUND EX INPUT

, if this option is installed). If the switch is in the 

DIGITAL 

 posi-

tion, input is from the 

DIGITAL INPUT

.

MAIN ANALOG INPUT

: Connect this to the cinema processor’s output. This is the input source of all film sound into the 

DCM unit if the 

INPUT SELECT 

switch is set to the 

ANALOG

 position. The 25-pin connector is an industry standard type 

and pinout; cables are available from cinema supply houses.

SURROUND EX INPUT (OPTION CARD)

: This input provides additional inputs when using a Dolby CP650 with the 

Cat.790 or Cat.791 option cards. The surround, backwall surround, and left extra/right extra channels are input through 
this connector. The 

INPUT SELECT 

switch must be set to 

ANALOG

 in order to use this connection.

DIGITAL INPUT

: If using a Dolby CP650 with Cat.778 option, connect the CP650 digital output to this connector. Set the 

INPUT SELECT 

switch to 

DIGITAL 

to select the digital input.

USB Connection

: Connect to USB port on the host PC. Communication between the DCM Manager software (running on the host 

PC) and the DCM is routed throught this connection. 

Firmware Update Mode Select

: This recessed push button switch is located directly left of the 

USB 

port. To place the DCM 

in firmware update mode, press inward and hold  the switch in the depressed position while turning the AC 

POWER

 switch on. 

Use a small tool, such as the end of a paperclip wire or similar object to depress the switch. The AC power must be off before 
initiating this sequence. Release the switch once the AC power has been applied. The DCM Manger software may then be used 
to continue the update procedure (refer to the software help file for details).

Summary of Contents for DCM 10

Page 1: ...DCM Series Digital Cinema Monitor Crossover System User Manual DCM 10 DCM 10D DCM 30 DCM 30D TD 000265 00 TD 000265 00 A...

Page 2: ...or moisture does not operate normally or has been dropped 15 When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions may be created by an uneven weight distri...

Page 3: ...circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or TV technician for help THIS PRODUCT IS INTENDED FOR CONNECTION TO A TN OR IT POWER SYSTEM S...

Page 4: ...ng Control In addition to the monitoring of your amplifier s audio I O your DCM includes QSC s exclusive Load Fault detection feature The DCM monitors for possible loudspeaker system or wiring faults...

Page 5: ...he signal from analog to digital and back again which is designed to minimize all background noise and react to the dynamic range of any film track 4 Loudspeaker Database pre programmed settings QSC h...

Page 6: ...Monitor Loudspeaker On the rear panel are a set of screw terminals marked EXTERNAL SPKR These are for connection to an external monitor loudspeaker As shipped from the factory a jumper between the IN...

Page 7: ...4 Subwoofer output 5 Alternate equalization select input 6 Auxiliary audio input 7 Hearing impaired output 8 Emergency bypass level controls and switch 9 Main analog input from cinema processor 10 Ana...

Page 8: ...ermines the function of the Monitoring Select but tons to the right of the AMPS PROC button The LEDs directly over the AMPS PROC button indicate what selected function the Monitor Select buttons will...

Page 9: ...t on all amplifier outputs To sense real world conditions these measurements must be found to be out of range several times before the Load Fault condition is indicated on the front panel If you are s...

Page 10: ...io power INPUT SELECT Switch Use this switch to select the input source of the DCM In the ANALOG position input is from the MAIN ANALOG INPUT and the SURROUND EX INPUT if this option is installed If t...

Page 11: ...nal to the EXTERNAL SPKR terminal SUB OUT provides the identical audio as the subwoofer DataPort This connection cannot be monitored or include any of the Fault Analysis functions because there are no...

Page 12: ...chassis and rack can be damaged if the DCM is not properly supported Unless the DCM is being installed in its final fixed location QSC strongly recommends supporting the rear of the unit Rear rack ear...

Page 13: ...ettings to the DCM hardware s flash memory and the DCM hardware can be disconnected from the host PC NOTE QSC updates these files regularly as new models are introduced from loudspeaker manufacturers...

Page 14: ...operating voltage information printed on it Locate the sticker note the rated voltage and ensure the AC circuit you intend to use is properly rated Locate the IEC style AC power cord supplied with yo...

Page 15: ...Ch 1 and Subcode 1 4 I MON Ch 1 and Subcode 2 5 Clip Protect Ch 1 6 Hard Ground 7 Ch 1 Plus Signal 8 Ch 2 Plus Signal 9 15V from Amplifier 10 Data Reference Ground 11 Ch 2 Minus Signal 12 Amplifier I...

Page 16: ...Description 1 not used 2 not used 3 Back Surround Left 4 not used 5 not used 6 Back Surround Right 7 Ground Digital Inputs 8 not used 9 Right Extra 10 Surround Left 11 Surround Right 12 not used 13 no...

Page 17: ...T 22 AES4 Bsl Bsr OUT 23 AES2 C SW OUT 24 AES2 C SW OUT 25 Chassis Ground Hearing Impaired The Hearing Impaired output signal is available on the screw terminal connector on the rear of the DCM The ou...

Page 18: ...oise pick up than unbalanced connections External Speaker Connection The monitor signal is available on the screw terminals at the rear of the DCM This pow ered signal can be connected directly to an...

Page 19: ...to the sound while in the Bypass position While in the bypassed position adjust the potentiometers to most closely match the normal position sound 3 Monitoring audio mix adjustments The DCM Manager s...

Page 20: ...audible but all attempts to get it louder fail connect the DCM to a PC running DCM Manager software and check the Monitor Attenuation Levels settings on the Monitor Setting page These settings have a...

Page 21: ...f switching the BYPASS to EMERGENCY does not restore sound to the center channel Verify the DCM is receiving input signals from the Cinema Processor Verify connections from the Cinema Processor to the...

Page 22: ...0 01 Analog in 0 008 Digital in 20 Hz to 20 kHz all filters flat Frequency Response 20 Hz to 20 kHz D to A Conversion 24 bit delta sigma 128x oversampled Filter Topology 24 bit digital IIR Crossover...

Page 23: ...Dimensions 19 wide x 5 25 high x 15 deep Weight 16 5 lbs 7 2 kg Line Voltage 100 VAC 240 VAC 50 60 Hz Safety Agency Approvals UL 60950 1 CSA RoHS WEE IEC 60950 1 EMC Approvals FCC Class B Connectors...

Page 24: ...ions via pre paid transportation with a copy of proof of purchase i e sales receipt This warranty provides that the examination of the return product must indicate in our judgment a manufacturing defe...

Reviews: