Maintenance
34
UM Pallet dispenser PD2 v2.0 EN
6 Maintenance
6.1 General
Note
•
The maintenance as described in this chapter is based
on 2000 running hours per year. Adjust the maintenance
frequency to the actual number of running hours per
year.
•
If required, Qimarox can carry out the maintenance
activities.
6.2 Specific safety regulations
For the proper functioning of the machine the various machine parts must be regularly
maintained. In this way defects and inaccuracies of the machine are prevented.
WARNING
•
Only a qualified maintenance engineer is allowed to carry
out maintenance activities on the machine. Refer to
chapter 3.
•
Working on the machine or on the lifting drive of the machine
may be started only if the carriers are prevented from
unintentional movement or falling.
•
Empty the (de)stacker and put the carrier into the lowest position
before starting any maintenance or repair activities.
•
Turn off the power supply to the machine with the main
switch before starting any maintenance or repair
activities. Secure the main switch with a padlock.
•
Switch off air service unit before starting any
maintenance or repair tasks. After the air service unit is
switched off, it is necessary to vent all cylinders (see
figures underneath).
•
Take the appropriate measures for safely working at
heights.
WARNING
Danger of moving parts. When venting, the cylinder and
parts of the machine may start moving, thus creating
crushing and other hazards. Keep away from moving parts
during venting to prevent injury.