background image

 

 

 

 

 

 

 

Installation & Start-Up Procedures 

Two-Tank Combo Water  

Softener & Filter 

Single Tank Combo Water  

Softener & Filter 

Water Softener

 

 

 

Congratulations! 

 

You’ve selected our best-selling 
water conditioning models for top 
performance and economy.   

 

Safety Zone Signature Series  
water conditioning systems are 
designed to provide years of 
service with proper care and 
maintenance.   

 

Hopefully, this manual will be 
beneficial and provide information 
you need to install, start-up and 
maintain your system.  
 
To view our valve manuals visit 

www.safetyzonewater.com

 

 

®2020 Safety Zone Water Systems, LLC 

 

Valve type 

Metered 

Valve sizes 

1”, 1.25”, 1.5” and 2” 

Pipe fittings available 

¾”, 1”, 1.25” and 1.5” 

Regeneration method 

Down flow 

Riser tube size 

1.05”, 1.25”, 1.5”and 2” 

Drain line fitting 

¾” male NPT 

Brine line 

3/8” quick connect 

Supply voltage 

120 V AC 

Supply frequency 

60 Hz 

Output voltage 

12 V AC 

Resin volume (cubic feet) 

1.0, 1.5, 2.0, 3.0, 4.0, 7.0 & 10 

Resin type 

8% crosslinked 

Carbon type (Combo units) 

Catalytic coconut shell 

KDF (Combo units) 

KDF-55 foam cubes  

Brine tank volume 

200 lbs. 

Brine tank overflow prevention 

Included 

By-pass valve 

Included 

 

 

Specifications 

 

 

 

 

 

 

Summary of Contents for Signature Series

Page 1: ...and maintain your system To view our valve manuals visit www safetyzonewater com 2020 Safety Zone Water Systems LLC Valve type Metered Valve sizes 1 1 25 1 5 and 2 Pipe fittings available 1 1 25 and 1 5 Regeneration method Down flow Riser tube size 1 05 1 25 1 5 and 2 Drain line fitting male NPT Brine line 3 8 quick connect Supply voltage 120 V AC Supply frequency 60 Hz Output voltage 12 V AC Resi...

Page 2: ... tank going up 14 When the valve goes into service open outlet on the valve to supply water to the house 15 Add salt to the brine tank 3 4 bags initially Valve Programming Safety Zone Water Signature Series electronic control valve The Safety Zone Signature Series valve is highly versatile and can be programmed for water softeners and Combo softener Filter systems Valves are available in 1 1 1 4 1...

Page 3: ...on of the drain line is critical to the system s performance Use drain line PVC or 1 PVC for best results When using tubing install the tube insert provided and connect tubing to drain line fitting with nut provided Water test It is essential to complete a water test prior to start up and valve programming Check the following parameters Hardness pH Iron well water Hydrogen Sulfide well water Chlor...

Page 4: ...tlet closed initiate a manual regeneration and follow these directions 1 Press REGEN button and hold button for 3 5 seconds for immediate regen 2 Let the valve advance to BACKWASH 3 Open valve s inlet slowly 1 3 to fill mineral tank 4 Allow air to escape listen until spurting stops 5 When water flows from drain open inlet valve fully 6 Make sure drain line is not restricted Note Do not tee drain l...

Reviews: