QED Environmental Systems
AP-3 Manual
Page 80
If the yield of the well is less than the maximum pump rate predicted by the appropriate flow
rate graph, multiply the actual fluid recovery rate times the air use factor. This air use can
be diminished if the regulator pressure is reduced. The maximum pump rate for the lower air
pressure can be predicted using the performance curves.
Note:
These air use factors are only applicable for the designated well head
conditions. Any additional resistance from out-of-well equipment (e.g.
surface hoses, valves, etc.) will affect the factors shown on these curves.