QED Environmental Systems
AP-3 Manual
Page 64
Equipment Cleaning Requirements
If the equipment is to be shipped to another site or to the factory for service, it needs to be
thoroughly cleaned before leaving the site. Cleaning the equipment protects the user (sender),
the shipper, and the receiver from dirt and/or contaminants. If the equipment is not cleaned
prior to shipping for servicing, it may be severely delayed, refused or the shipper may be
charged a cleaning fee. Before packing and shipping, ensure that the equipment is dry inside
and out.
The following is a list of equipment and how it should be cleaned prior to shipment.
Hoses and Fittings
STEP 1 -
Pump clean water or water with a gentle soap solution (e.g. Dove Dish
Soap) through the pump to remove free product and particles.
STEP 2 -
Rinse all soap off of the equipment.
STEP 3 -
Soak and rinse the outside of the unit with water to remove loose debris
and dirt.
STEP 4 -
Steam clean inside and out to remove difficult dirt and contaminants.
Caution:
Use low pressure (less than 40 psi) when steam cleaning.
AutoPumps
STEP 1 -
Pump clean water or water with a gentle soap (e.g. Dove Dish Soap)
solution through the pump to remove free product and particles.
STEP 2 -
Rinse all soap off of the equipment.
STEP 3 -
Soak and rinse the outside of the unit with water to remove loose debris
and dirt.
STEP 4 -
Steam clean inside and out to remove difficult dirt and contaminants.
Caution:
Use low pressure (less than 40 psi) when steam cleaning.
Summary of Contents for AutoPump AP-3
Page 18: ...Page 9 AP 3 Manual Revision 3 April 2009 Figure 3 How it Works 601345 Chapter 2 Overview...
Page 25: ...QED Environmental Systems AP 3 Manual Page 16 Figure 5 Long and Short Bottom Loading AP 3 BL...
Page 37: ...QED Environmental Systems AP 3 Manual Page 28 Figure 12 Locking Quick Connects 600259 02...
Page 41: ...QED Environmental Systems AP 3 Manual Page 32 Figure 16 AP 3 Assembly Well Cap with Hose Barbs...
Page 47: ...QED Environmental Systems AP 3 Manual Page 38 Figure 19 Hose Bundling Part 2 of 2 600487 03...
Page 57: ...QED Environmental Systems AP 3 Manual Page 48 Figure 20 Removing AP 3 Pump Casing...
Page 119: ...QED Environmental Systems AP 3 Manual Page 110 Log Notes...