HSC505 - E 8-32 Zone LCD Home Security Controller - Installation Manual
________________________________________________________________________________
Page 46
This document and product are copyrighted and all rights are reserved.
QUESTION 119
Remote 10
Location 1 = button 1,
Location 2 = Button 2
Location 3 = button 3,
Location 4 = Button 4.
Triggers:
QUESTION 128 - QUESTION 155
The system has 5 onboard programmable voltage trigger outputs and allows for 50 programmable options.
The individual trigger output polarity is programmed in QUESTION 108 - L1 & L2.
Location 1
= A 3-digit input for the trigger function.
Location 2
= A 2-digit input assigning the trigger number.
Location 3
= A 1-digit input assigning the trigger output action.
Location 1:
Three digit trigger event.
NOTE 1: Zones selected as triggered in the disarm state, may only be selected as timed.
Trigger events Zones:
Trigger event
Zone #
Zone #
Zone #
Zone #
Disabled
000
000
000
000
Zone 1 to 4 triggered (armed)
001
002
003
004
Zone 5 to 8 triggered (armed)
005
006
007
008
Zone 9 to 12 triggered (armed)
009
010
011
012
Zone 13 to 16 triggered (armed)
013
014
015
016
Zone 1 to 4 triggered (disarmed)
017
018
019
020
Zone 5 to 8 triggered (disarmed)
021
022
023
024
Zone 9 to 12triggered (disarmed)
025
026
027
028
Zone 13 to 16 triggered (disarmed)
029
030
031
032
Zone 1 to 4 restore
033
034
035
036
Zone 5 to 8 restore
037
038
039
040
Zone 9 to 12 restore
041
042
043
044
Zone 13 to 16 restore
045
046
047
048
Zone 1 to 4 tamper
049
050
051
052
Zone 5 to 8 tamper
053
054
055
056
Zone 9 to 12 tamper
057
058
059
060
Zone 13 to 16 tamper
061
062
063
064
Downloaded from
www.Manualslib.com
manuals search engine