HSC505 - E 8-32 Zone LCD Home Security Controller - Installation Manual
________________________________________________________________________________
Page 35
This document and product are copyrighted and all rights are reserved.
Remote or onboard expansion
QUESTION 58
Selects zones 9 to 16 of being either plug in on the control panel or being on a remote expander.
Location 1 = Zone 9 to 16 expansion,
Location 2 = Reserved,
Location 3 = Error beep enable,
Location 4 = Telco fault timer.
Location 1
0
Onboard
1
Remote
Location 3
0
Disable
1
Enable
Location 4
0
Disable
1
2 minutes
2
4 minutes
3
6 minutes
4
8 minutes
5
10 minutes
6
12 minutes
7
14 minutes
8
16 minutes
9
18 minutes
A
20 minutes
B
22 minutes
C
24 minutes
D
26 minutes
E
28 minutes
F
30 minutes
QUESTION 59
AUTO TEST TIME
Sets the time that the land-line communicator and/or the serial TX will transmit a test signal. The delay period
between these signals being set in Question 52 - L1.
Location 1 = Hours x 10,
Location 2 = Hours x 1,
Location 3 = Minutes x 10,
Location 4 = Minutes x 1.
Downloaded from
www.Manualslib.com
manuals search engine