background image

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO BLK ML-G10/t

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO BLK ML-G10/t

2

3

Table of contents

1 Introduction

With solar modules from Hanwha Q CELLS America Inc. (here-
after referred to as "Qcells") you can directly transform the 
sun’s limitless energy into environmentally-friendly solar elec-
tricity. In order to ensure the maximum performance of your 
Qcells solar modules, please read the following instructions 
completely and carefully and observe all guidelines. Non-com-
pliance may result in damage and / or physical injury.

This installation manual provides instructions for the safe installa-
tion and operation of crystalline solar modules.

  Please read these instructions carefully before proceeding with 

your installation.

  Please retain these instructions for the life of the solar mod-

ules.

  Please ensure that this Manual is available to the operator at all 

times.

  This Manual should be given to all subsequent owners or users 

of the solar modules.

  All supplements received from the manufacturer should be in-

cluded.

  Please observe all other applicable documents.
  If your questions are not satisfactorily answered in the manual, 

please contact your system supplier.

Additional information can be found on our website at www.
qcells.com.

Intended use

This manual is valid in North America for Qcells solar modules. 
These instructions contain information regarding the safe han-
dling and use of quality crystalline solar modules from Qcells and 
their installation, mounting, wiring, maintenance.

Symbols and Labels

The following symbols and labels are used throughout the Manu-
al for ease of use.

SYMBOL

DESCRIPTION

Procedure with one or more steps.

Lists of items.

Ensure that when carrying out a procedure,
you check the results of said procedure.

Prohibited.

Beware of possible danger or damage. 
Categories:

 

Danger: Risk of fatal injury

 

Attention: Risk of serious injury or damage to 
property

 

Note: Risk of damage to product

Units

Where both Imperial and U.S. units (for example inches) are 
shown, metric units are definitive. References to “Data Sheet” or 
“Module Data Sheet” refer to the Module Data Sheet applicable 
to the module being used.

Safety Regulations

The installer and solar module operator are responsible for com-
pliance with all applicable statutory requirements and regulations.

  The following regulations and standards must be upheld at all 

times during the installation, operation, and maintenance of the 
solar modules:

 

Installation and Operation Manual.

 

Other applicable documents (such as country-specific reg-
ulations for pressure equipment, operational safety, hazard-
ous goods, and environmental protection).

 

Regulations and requirements specific to the system.

 

Applicable country-specific laws, regulations, and provisions 
governing the planning, installation, and operation of solar 
power systems and work on roofs.

 

Any valid international, national and regional regulations 
governing work with direct current, especially those appli-
cable to the installation of electrical devices and systems, 
and regulations issued by the respective energy provider 
governing the parallel operation of solar power systems.

 

Accident-prevention regulations.

Certified Personnel

Both, the operator and installer are responsible for ensuring that 
the installation, maintenance, connection to the grid, and dis-
mantling are carried out by trained and qualified electricians and 
engineers with approved training certificates (issued by a state or 
federal organization) for the respective specialist trade. Electrical 
work may only be performed by an officially certified tradesper-
son in accordance with the applicable safety standards, accident 
prevention regulations, and the regulations of the local energy 
provider. 

DOCUMENT REVISION 02
This installation manual is valid for North America as of February 1st 2023 for Q.PEAK DUO BLK ML-G10/t, Q.PEAK DUO BLK ML-G10+/t solar modules, and replaces all earlier versions.
DISCLAIMER
This manual is subject to change. The data sheets and customer information valid at the point in time when the relevant module was manufactured apply to the installation, mounting,
and maintenance procedures for the respective solar modules, as far as no updated document is provided.

1 Introduction 3

2 Planning 5

2.1 Technical specifications 

5

2.2 Requirements 6
2.3 Mounting options 

7

2.4 Electrical layout 

11

3 Installation 12

3.1 Safety and transport 

12

3.2 Preparation of installation 

14

3.3 Module installation 

15

4 Electrical Connection 

16

4.1 Safety 16
4.2 Electrical installation safety 

17

4.3 Connection of modules 

18

4.4 After installation 

19

5 Grounding 20

6 Faults and defects 

21

7 Disposal 21

8 Maintenance and cleaning 

22

Summary of Contents for Q.PEAK DUO BLK ML-G10/t Series

Page 1: ...Installation and operation manual Q PEAK DUO BLK ML G10 t solar module series ...

Page 2: ...ator are responsible for com pliance with all applicable statutory requirements and regulations The following regulations and standards must be upheld at all times during the installation operation and maintenance of the solar modules Installation and Operation Manual Other applicable documents such as country specific reg ulations for pressure equipment operational safety hazard ous goods and env...

Page 3: ...OR INCORRECT USE OF SOLAR MODULES VOIDS THE LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD AND RISK PROPERTY DAMAGE THIS INCLUDES IMPROPER IN STALLATION OR CONFIGURATION IMPROPER MAINTENANCE UNINTENDED USE AND UNAUTHORIZED MODIFICATION Attention This marking indicates that this product should not be disposed of with other household waste within the EU Recycle this product properly to prevent poss...

Page 4: ...Ensure that no additional forces are applied through the mount ing system into the module except for the wind and snow loads Additional forces and moments of torque at the mounting po sitions caused by torsions displacements or vibrations in the mounting system are not allowed Ensure that the clamps and the mounting frame are compatible Clamp System Recommendations Use customary clamps that satisf...

Page 5: ...m long side 11 8 17 7 300 450mm CL6c outer clamps 0 79 19 7 20 500mm middle clamps 25 2 48 8 640 1240mm 3600 3000 2400 2000 outer clamps 0 79 13 8 20 350mm middle clamps 25 2 48 8 640 1240mm 4000 4000 2660 2660 CL6d short side 0 79 9 84 20 250mm long side 25 2 48 8 640 1240mm 4000 3600 2660 2400 The below mounting options are only possible under certain conditions MOUNTING OPTION POSITION OF CLAMP...

Page 6: ... load 2 Planning 2 3 Mounting options 2 Planning 2 4 Electrical layout Module Selection For detailed key electrical data please refer to the actual data sheet referring to the relevant Module available at www qcells com For maximum energy yields mismatches of specified electric current IMPP of more than 5 should be avoided for all mod ules connected in series Safety Factor During normal operation ...

Page 7: ...ock Do not install damaged modules Inform your distributor of any damages immediately Warning Fire Risk Do not install modules indoors Do not install modules on moving objects 3 Installation 3 1 Safety and Transport Note Module damage may occur Do not stack modules Note Module damage may occur Do not install modules near flammable gas vapors Do not install modules in close proximity to air condi t...

Page 8: ... of fatal injury due to electric shock Only use dry insulated tools Do not carry out the installation alone Only install undamaged modules and components Do not modify the module e g do not drill any additional holes 3 Installation 3 3 Module installation Option 1 Fasten the module with 4 clamps in the specified clamping range see Fig 2 p 7 Tighten clamps according to manufacturer s instruc tions ...

Page 9: ...paration Be sure to observe the time intervals specified by the inverter manufacturer after switching off the inverter Make sure that the plugs can not be connected unintentionally Before working on the contacts check them for safety ex tra low voltage Danger Risk of fatal injury due to electric shock Only use dry insulated tools for electrical work Danger Risk of fatal injury due to electric shoc...

Page 10: ...her audibly Danger Risk of fatal injury due to electric shock Ensure that all electrical components are in a proper dry and safe condition To avoid complex cabling arrangements it is often advantageous to rotate some modules 180 Module orientation can clearly be identified from the front side by the serial number and barcode labelled behind the module glass on the side with negative connection cab...

Page 11: ...should be attached to the frame grounding hole using a stainless steel screw toothed lock washer or KEPS nut in order to penetrate the anodized layer and backing nut Care should be taken to avoid the use of grounding hardware of dissimilar metals which may lead to corrosion Option B Integrated grounding methods The Qcells modules can be bonded with the racking system us ing UL1703 or UL2703 certif...

Page 12: ...age may occur Remove snow and ice carefully without force e g with a very soft broom Do not scratch off dirt Module cleaning has to be done by qualified personnel ac cording to the state of the art and taking into account all rele vant safety issues and general product properties e g but not restricted to electrical safety mechanical stability load limits depending on the actual mounting options c...

Page 13: ...nstallation manual solar modules Q PEAK_DUO_BLK_ML G10 X t_modules_series_2023 02_Rev02_NA HANWHA Q CELLS AMERICA INC 400 Spectrum Center Drive Suite 1400 Irvine CA 92618 USA EMAIL WEB TEL hqc inquiry qcells com www qcells com 1 949 748 59 69 ...