INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO BLK ML-G10/t
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO BLK ML-G10/t
8
9
TYPE OF
INSTALLATION
POINT MOUNTING SYSTEM
LINEAR MOUNTING SYSTEM
Installation
with insertion
profiles
not permitted
IP1
2 Planning
2.3 Mounting options
Specifications
MOUNTING
OPTION
POSITION OF
CLAMPS* [in]
TEST LOAD
PUSH / PULL** [Pa]
DESIGN LOAD
PUSH / PULL** [Pa]
SAFETY
FACTOR
CL1a
5.11 - 13.8 (130 - 350 mm)
(Max. span: 55.1 (1400mm))
5400 / 4000
3600 / 2660
1.5
0.79 - 19.7 (20 - 500 mm)
(Max. span: 55.1 (1400mm))
5400 / 3000
3600 / 2000
0.79 - 25.6 (20 - 650 mm)
2400 / 2400
1600 / 1600
CL1b
11.8 - 19.7 (300 - 500 mm)
2400 / 2400
1600 / 1600
CL3
9.45 - 13.8 (240 - 350 mm)
4000 / 4000
2660 / 2660
FB1
15.6 (395.5 mm)
5400 / 4000
3600 / 2660
FB2
15.6 (395.5 mm)
4000 / 4000
2660 / 2660
IP1
-
3600 / 3300
2400 / 2200
CL5
short side: 0.79 - 3.94 (20 - 100 mm)
long side: 11.8 - 17.7 (300 - 450 mm)
CL6c
outer clamps:
0.79 - 19.7 (20 - 500 mm)
middle clamps:
25.2 - 48.8 (640 - 1240 mm)
3600 / 3000
2400 / 2000
outer clamps:
0.79 - 13.8 (20 - 350 mm)
middle clamps:
25.2 - 48.8 (640 - 1240 mm)
4000 / 4000
2660 / 2660
CL6d
short side:
0.79 - 9.84 (20 - 250 mm)
long side:
25.2 - 48.8 (640 - 1240 mm)
4000 / 3600
2660 / 2400
The below mounting options are only possible under certain conditions.
MOUNTING
OPTION
POSITION OF
CLAMPS* [in]
TEST LOAD
PUSH / PULL*** [Pa]
DESIGN LOAD
PUSH / PULL*** [Pa]
SAFETY
FACTOR
CL2a
(with rails)
0.79 - 3.94 (20 - 100 mm)
2400 / 2000
1600 / 1330
1.5
0.79 - 11.8 (20 - 300 mm****)
2400 / 1800
1600 / 1200
CL2b
(without rails)
0.79 - 7.87 (20 - 200 mm)
2000 / 2000
1330 / 1330
0.79 - 11.8 (20 - 300 mm)
1800 / 1800
1200 / 1200
*
**
***
****
Distance between outer edge of module and middle of the clamp; consider further details below.
Loads according to IEC 61215-2:2016 and UL 61730-2:2017
Loads according to IEC 61215-2:2016 and UL 61730-2:2017 except for design loads lower than 1600 Pa which do not fulfill the
requirements of the standards.
Rails must not be under the junction box.