8/16 Channel Digital Video Recorder
25
If there is more than one DVR in a local area network, each DVR must be set to have an exclusive MAC
Address. There is only one chance to modify the MAC Address. Once the MAC ADDRESS is
changed, this menu will not appear again. If you want to change the MAC ADDRESS again, the factory
default settings have to be reloaded with Factory Reset. Move the cursor to FACTORY RESET in the
SYSTEM SETUP menu, pressing ENTER will prompt you to INITIALIZE. Enter YES, DVR settings
revert to default.
MAC addresses are 12-digit hexadecimal numbers (48 bits in length). For MAC ADDRESS set the first
two byte sets to 00.00, and change the other bytes.
20. Sensor Setup
Move the cursor to SENSOR SET in the SETUP MODE Top Main Menu, pressing the ENTER button
results in the SENSOR SETUP menu window appearing. This is illustrated below. Press up or down
arrow buttons to move the cursor. Press the ADD or DEC buttons in the front panel (“-SET+”on the
remote control) to change the setting. Setup individually, for each channel with sensor, using
CHANNEL SELECT.
The following Setup Options are available for each selected channel:
ALARM ENABLE:
Alarm trigger switch that can be set to OFF, LOW LEVEL or HIGH LEVEL; if set
to OFF, the DVR will ignore the alarm input.
MOTION ENABLE:
Motion alarm switch that can be set to ON or OFF; if set to OFF, the motion
alarm will be ignored.
MOTION LEVEL:
Motion sensitivity level. If the moving object in the picture is small relative to the
screen output, set to HIGH or VERY HIGH. The default level is NORMAL.
BUZZER TIME:
Buzzer sound duration when there is a sensor or motion alarm triggered.