INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G10.2_G10.c – Q CELLS
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G10.2_G10.c – Q CELLS
2 PLANNING
2.3 MOUNTING OPTIONS
TYPE OF
INSTALLATION
POINT MOUNTING SYSTEM
LINEAR MOUNTING SYSTEM
INSTALLATION
WITH INSERTION
PROFILES
TRACKER
INSTALLATION
ON MOUNTING
POINTS
TRACKER
INSTALLATION
WITH CLAMPS
TB1a
908
EN
TB2a
EN
908
908 /
713 /
454
EN
TB1b
713
TB2b
EN
713
713 /
454
TC1
908 -
958
EN
IP1
IP2
2 PLANNING
2.3 MOUNTING OPTIONS
Specifications
MODULE TYPE
MOUNTING
OPTION
POSITION OF CLAMPS*
[MM]
TEST LOAD
PUSH / PULL** [PA]
DESIGN LOAD
PUSH / PULL** [PA]
SAFETY
FACTOR
Q.PEAK DUO XL-G10.2
Q.PEAK DUO XL-G10.c
FB1
454
5400 / 3000
3600 / 2000
1.5
CL1a
300 - 550
5400 / 2400
3600 / 1600
FB2
454
3600 / 3000
2400 / 2000
mFB2
454
3400 / 3000
2260 / 2000
CL3 / mCL3
300 - 550
3600 / 3000
2400 / 2000
IP1
-
TB1b
713
TB2b
Outer side: 713
Inner side: 713 / 454
CL1b
300 - 550
3000 / 2400
2000 / 1600
TB1a
908
2500 / 2400
1660 / 1600
TB2a
Outer side: 908
Inner side: 908 / 713 / 454
2700 / 2400
1800 / 1600
CL5
short side: 20 - 100
long side: 400 - 550
3000 / 2400
2000 / 1600
Ä
The below mounting options are only possible under certain conditions.
MODULE TYPE
MOUNTING
OPTION
POSITION OF CLAMPS*
[MM]
TEST LOAD
PUSH / PULL*** [PA]
DESIGN LOAD
PUSH / PULL*** [PA]
SAFETY
FACTOR
Q.PEAK DUO XL-G10.2
Q.PEAK DUO XL-G10.c
TC1
908 - 958
2400 / 2200
1600 / 1460
1.5
CL1a
20 - 550
2400 / 2000
1600 / 1330
CL2a (with
rails)
20 - 100****
2400 / 1600
1600 / 1060
CL2b (with-
out rails)
20 - 100
1600 / 1600
1060 / 1060
*
**
***
****
Distance between outer edge of module and middle of the clamp (see table „2.3 Mounting Options“ on page 7); consider further details below.
Loads according to IEC 61215-2:2016 and UL 61730.
Test procedure according to IEC 61215-2:2016 and UL 61730. Loads for these mounting options do not fulfill the requirements of the standards.
Rails must not be under the junction box.