Important Safety Information 

Read this First

 

To install AC Modules (solar panels), read and follow all warnings and instructions in this guide. Safety precautions 

are listed at the back of this guide. 
The Enphase Microinverters that are pre-installed on the backs of the ACM do not require grounding electrode 

conductors (GEC), equipment grounding conductors (EGC), or grounded conductor (neutral). The microinverter has a 

Class II double-insulated rating, which includes ground fault protection (GFP). 

IMPORTANT: 

The ACM requires the Q Cable and is not compatible with previous Enphase cabling. An IQ Envoy is 

required to monitor performance of the ACMs. The Q Accessories work only with Enphase IQ Series Microinverters. 

 

Product Labels

 

The following symbols appear on the 

product label

 and are described here: 

 

WARNING

: Hot surface. 

DANGER

: Refer to safety instructions. 

DANGER

: Risk of electrical shock. 

Refer to manual 

Double-insulated

 

 

Safety and Advisory Symbols 

To reduce the risk of electric shock, and to ensure the safe installation and operation of the Enphase

 

IQ System, the 

following safety symbols appear throughout this document to indicate dangerous conditions and important safety 

instructions. 

 

DANGER

 

This indicates a hazardous situation, which if not avoided, will result in death or serious injury. 

WARNING

 

This indicates a situation where failure to follow instructions may be a safety hazard or cause 

equipment malfunction. Use extreme caution and follow instructions carefully. 

WARNING

 

This indicates a situation where failure to follow instructions may result in burn injury. 

  NOTE:

 

 

This indicates information that is very important for optimal system operation. Follow 

instructions closely. 

 

 

Installation and Operation Manual 

 

 2020 Enphase Energy Inc. All rights reserved. 

 

 

IQ 7+ Microinverter Safety Instructions 

General Safety 

 

DANGER

: Risk of 

electric shock. Risk 

of fire.

 

Only use electrical system components approved for wet locations. 
Only qualified personnel should install, troubleshoot, or replace Enphase Microinverters or 

Enphase Q Cable and Accessories. 
Ensure that all AC and DC wiring is correct and that none of the AC or DC wires are pinched, 

shorted or damaged. Ensure that all AC junction boxes are properly closed.  
Do not exceed the maximum number of microinverters in an AC branch circuit as listed in the 

manual. You must protect each microinverter AC branch circuit with a 20 A maximum breaker 

or fuse as appropriate. 

DANGER

: Risk of 

electric shock.

 

Do not use Enphase equipment in a manner not specified by the manufacturer. Doing so may 

cause death or injury to persons, or damage to equipment. 
Be aware that installation of this equipment includes risk of electric shock.  
The DC conductors of this photovoltaic system are ungrounded and may be energized. 
Always de-energize the AC branch circuit before servicing. Enphase does not recommend 

disconnecting the DC connectors under load. 

WARNINGS: 

Before installing or using the Enphase Microinverter, read all instructions and cautionary 

markings in the technical description, on the Enphase equipment and on the photovoltaic (PV) 

equipment. 
Do not connect Enphase Microinverters to the grid or energize the AC circuit(s) until you have 

completed all of the installation procedures and have received approval from the electrical 

utility company. 
When the PV array is exposed to light, DC voltage is supplied to the power conversion 

equipment (PCE). 
Risk of equipment damage. Enphase male and female connectors must only be mated with the 

matching male/female connector. 

NOTES: 

To ensure optimal reliability and to meet warranty requirements, install the Enphase equipment 

according to the instructions in this manual. 
The AC and DC connectors on the cabling are rated as a disconnect only when used with an 

Enphase Microinverter. 
Protection against lightning and resulting voltage surge must be in accordance with local 

standards.  

 

Perform all electrical installations in accordance with all applicable local electrical codes, such 

as: the Canadian Electrical Code, Part 1; ANSI requirements; and NPFA 70 (NEC). 

 

Microinverter Safety 

 

WARNING

: Risk of 

skin burn. 

 

The body of the Enphase Microinverter is the heat sink. Under normal operating conditions, the 

temperature could be 20° C above ambient, but under extreme conditions the microinverter 

can reach a temperature of 90° C. To reduce risk of burns, use caution when working with 

microinverters. 

DANGER

: Risk of 

electric shock. Risk 

of fire.

 

Only qualified personnel may connect the Enphase Microinverter to the utility grid. 
Do not attempt to repair the Enphase Microinverter; it contains no user-serviceable parts. If it 

fails, contact Enphase customer service to obtain a return merchandise authorization (RMA) 

number and start the replacement process. Tampering with or opening the Enphase 

Microinverter will void the warranty. 

WARNING

: Risk of 

equipment damage 

 

The Enphase Microinverter is not protected from damage due to moisture trapped in cabling 

systems. Never mate microinverters to cables that have been left disconnected and exposed to 

wet conditions. This voids the Enphase warranty. 

NOTES: 

The Enphase Microinverter has field-adjustable voltage and frequency trip points that may 

need to be set, depending upon local requirements. Only an authorized installer with the 

permission and following requirements of the local electrical authorities should make 

adjustments. 

 

Summary of Contents for Q.PEAK DUO BLK-G6+/AC

Page 1: ...Valid for North America INSTALLATION AND OPERATION MANUAL Q PEAK DUO BLK G6 AC Solar Module Series ...

Page 2: ... The following regulations and standards must be upheld at all times during the installation operation and maintenance of the solar modules Installation and Operation Manual Other applicable documents such as country specific regu lations for pressure equipment operational safety hazardous goods and environmental protection Regulations and requirements specific to the system Applicable country spe...

Page 3: ...tallation manual is only valid in combination with the following technical information DOCUMENT TYPE Product data sheet Packaging and transport information MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS THE LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD AND RISK PROPERTY DAMAGE THIS INCLUDES IMPROPER INSTALLATIONORCONFIGURATION IM PROPERMAINTENANCE UNINTENDED USE AND UNAUTHORIZED MODIFICATION DON...

Page 4: ... if required by the utility 2 PLANNING 2 1 TECHNICAL SPECIFICATIONS Topic Unit Min Typical Max MISCELLANEOUS PARAMETERS Maximum Microinverters per 20 amp Branch Circuit 240 VAC single phase 208 VAC single phase A 13 11 CEC Weighted Efficiency 240 VAC single phase 208 VAC single phase 97 0 96 5 Static MPPT Efficiency weighted ref EN 50530 99 0 Total Harmonic Distortion 5 Ambient Temperature Range C...

Page 5: ...ensuring that maximum power available from each PV module is exported to the utility grid regardless of the performance of the other PV modules in the array While an individual PV module in the array may be affected by shading soiling orientation or PV module mismatch each Enphase MicroinverterensurestopperformanceforitsassociatedPVmodule System Monitoring Once you install the Enphase IQ Envoy or ...

Page 6: ...ording to chapter 2 3 Test Load in accordance with IEC 61215 and Design Load 1 5 in accor dance with UL 1703 Installation using a mounting structure for solar modules Mounting Structure Requirements Requirements for the mounting structure Conforms to the necessary structural requirements Compliant with local snow and wind loads Properly fastened to the ground the roof or the façade Forces acting o...

Page 7: ...ductorlengthsintheVoltageRiseTechnicalBriefatenphase com support Refer to this brief for voltage rise values in Enphase Q Cables and on how to calculate voltage rise in other wire sections of the system Standard guidelines for voltage rise on feeder and AC branch circuit conductors might not be sufficient for microinverter AC branch circuits that contain the maximum allowable microinverters This i...

Page 8: ...OSITION OF CLAMPS MM TEST LOAD PUSH PULL PA DESIGN LOAD PUSH PULL PA SAFETY FACTOR IP2 2400 2200 1600 1470 1 5 Distance between outer edge of module and middle of the clamp consider further details below Loads according to IEC 61215 2 2016 and UL 1703 Test procedure according to IEC 61215 2 2016 and UL 1703 Mounting options do not fulfill the requirements of the standards ATTENTION Ä The loads in ...

Page 9: ... percent 80 percent derating which may be applicable Module Connection Detailed information about interconnecting modules are specified in section 9 Appendix on page 28 NOTE When installing different product versions the lowest minimum permitted reverse current load capacity applies 2 PLANNING 2 6 ELECTRICAL LAYOUT 3 INSTALLATION 3 1 SAFETY AND TRANSPORT Ä Leave modules in their original packaging...

Page 10: ...er step on modules Ä Do not subject modules to any mechanical stress Ä Do not allow any objects to fall onto modules 3 INSTALLATION 3 1 SAFETY AND TRANSPORT DANGER Risk of fatal injury due to electric shock Ä Block off the installation zone Ä Keep children and unauthorized individuals away from the solar power system DANGER Risk of fatal injury due to electric shock Ä Ensure that modules and tools...

Page 11: ... the valid national regulations and safety guidelines for the installation of electrical devices and systems Ä Make sure to take all necessary safety precautions With mod ule or phase voltages of more than 120V the safety extra low voltage range is exceeded Ä Carry out work on the inverter and the wiring with extreme caution Ä Ensure that the modules are disconnected at the inverter prior to separ...

Page 12: ...s a heat sink Under normal operating conditions the temperature could be 20 C above ambient but under extreme conditions the microinverter can reach a temperature of 90 C To reduce risk of burns use caution when working with microin verters 90 C Ä Only use connector and solar cables provided from Enphase Q Cable please see page 8 Ä Only interconnect connectors of the same type and manufacturer Ä U...

Page 13: ...e Q CELLS frames and modules reference should be made to local statutes and regulations for specific requirements on grounding The U S National Electrical Code addresses these issues in Article 250 Proper grounding is achieved by bonding all exposed non current carrying metal equipment to the appropriately sized equipment grounding conductor EGC or racking system that can be used for integrated gr...

Page 14: ...ed by dirt or debris e g plants bird droppings it needs to be cleaned to prevent a loss of performance Maintenance Ä The PV system has to be inspected regularly by certified personnel Ä The time intervals and extent of the inspection can depend on local circumstances e g salt ammonia content in the air high humidity etc The customer operator must inform him herself about time intervals and extend ...

Page 15: ... shock Do not use Enphase equipment in a manner not specified by the manufacturer Doing so may cause death or injury to persons or damage to equipment Be aware that installation of this equipment includes risk of electric shock The DC conductors of this photovoltaic system are ungrounded and may be energized Always de energize the AC branch circuit before servicing Enphase does not recommend disco...

Page 16: ...ially explosive environments Do not allow the terminator to come into contact with open flame Fit the terminator cap using only the prescribed tools and in the prescribed manner Use the terminator to seal the conductor end of the Enphase Q Cable no other method is allowed Installation and Operation Manual 2020 Enphase Energy Inc All rights reserved 7 PV Rapid Shutdown Equipment PVRSE This product ...

Page 17: ...voltage at the site is within range Service Type and Voltage L1 L2 240 V Split Phase 211 to 264 VAC 208 V Single Phase 183 to 229 VAC B Install a junction box at a suitable location on the racking C Provide an AC connection from the junction box back to the electricity network using equipment and practices as required by local jurisdictions Step 2 Position and Connect the Enphase Q Cable A Plan ea...

Page 18: ... turn only the hex nut to prevent conductors from twisting out of the separator NOTE Turn only the hex nut to prevent conductors from twisting out of the separator G Attach the terminated cable end to the PV racking with a cable clip or tie wrap so that the cable and terminator do not touch the roof WARNING The terminator cannot be re used If you unscrew the nut you must discard the terminator 13m...

Page 19: ...ips Cable clip B Dress any excess cabling in loops so that it does not contact the roof Do not form loops smaller than 12 cm 4 in diameter Installation and Operation Manual 2020 Enphase Energy Inc All rights reserved 18 Step 8 Ground the ACMs Choose to use grounding clamps or module mounting holes to ground the modules Or you can use a reliable third party grounding system All Methods A Ground the...

Page 20: ...er to DC Resistance Low Power Off Condition on page 40 The Microinverter LED Installation and Operation Manual 2020 Enphase Energy Inc All rights reserved 20 Step 10 Set Up and Activate Monitoring Refer to the Enphase IQ Envoy Quick Install Guide to install the IQ Envoy and set up system monitoring and grid management functions This guide leads you through the following Connecting the IQ Envoy Det...

Page 21: ...d the microinverter stops power production and raises this condition This may indicate defective module insulation defective wiring or connectors moisture ingress or a similar problem Although the cause may be temporary this microinverter condition persists until the sensor is manually reset An IQ Envoy is required to clear this condition The condition clears on operator command unless its cause i...

Page 22: ...ables from the PV module to measure microinverter current This will be under one amp if AC is disconnected K Verify the PV module DC voltage is within the allowable range shown in Specifications on page 6 of this manual Installation and Operation Manual 2020 Enphase Energy Inc All rights reserved 24 L Following the steps in Remove and Replace a Microinverter remove the PV panel from the roof and s...

Page 23: ...y O Ship the old microinverter to Enphase using the supplied return shipping label Microinverter Communications LED Device Scan button Installation and Operation Manual 2020 Enphase Energy Inc All rights reserved 26 Enphase Q Cable Planning and Ordering The Enphase Q Cable is a continuous length of 12 AWG double insulated outdoor rated cable with integrated connectors for microinverters These conn...

Page 24: ...horized installer following the requirements of the local electrical utility is allowed to make Grid Profile adjustments NOTE Grid profile changes are applied only after a microinverter is detected In some regions and in some situations microinverter trip points may be adjusted to account for high grid voltage or for local conditions Grid profile management tasks include Set the grid profile for y...

Page 25: ...pectrum Center Drive Suite 1400 Irvine CA 92618 USA TEL 1 949 748 59 69 EMAIL inquiry us q cells com WEB www q cells us Subject to change without notice Q CELLS Installation manual solar modules Q PEAK DUO BLK G6 _AC_2020 07_Rev02_NA ...

Reviews: