17
INSTALLATION AND OPERATION MANUAL FOR FLAT ROOF SYSTEM Q.FLAT-G6 – Q CELLS
4
ASSEMBLY
4.6 MOUNT AND SCREW ON MODULE CLAMPS H
PRELIMINARY WORK:
Place the modules centrally on the tower
E
and base
C
.
PROCEDURE:
Place the middle and end clamps
H
on the side of the tower
E
,
facing the base
C
on the lower guide groove and press on the
opposite guide groove until the click latch engages with an audible
noise. Ensure that the middle and end clamps
H
are securely and
seated flush in the guide grooves.
Place the middle and end clamps
H
on the side of the base
C
,
facing the tower
E
on the upper guide groove and press on the
opposite guide groove until the click latch engages with an audible
noise. Ensure that the middle and end clamps
H
are securely and
seated flush in the guide grooves.
Place the modules and ensure that they are centred on the tower
E
and base
C
. Ensure that the middle and end clamps
H
are flush
and clean with the module. Tighten the locking screws. The instal-
lation instructions of the module manufacturers must be observed.
Observe the tightening torque of 10 Nm. (Please observe the note
MAINTENANCE)
NOTE:
Incorrectly installed middle and end clamps
H
that are removed again must be replaced with new components. It must be ensured
that the torque specification is adhered to. Otherwise there is a risk of damaging components and impairing stability.
MIDDLE CLAMP
END CLAMP
CORRECT
INCORRECT