1 2
TECHNICAL SPECIFICATION
12.1
Power supply.
Power input:
230V
version
:
230V ac +/- 10% 50Hz/60Hz.
220V
version
:
220V ac +/- 10% 50Hz/60Hz.
Power input fuse:
230, 220V versions
:
250mA quick blow.
Low voltage output
:
13.2 Vdc fused, 1.25 Amp maximum
Including Central Panel. 1Amp
maximum available for external devices.
Low voltage output fuses
:
1 Amp quick blow.
Battery charge voltage
:
13.7 Vdc.
Rechargeable battery capacity
:
12V sealed lead acid, 1.2 to 6 AH.
12.2
Control PCB
.
Current consumption
(day mode)
:
206mA.
(set mode)
:
179mA.
(alarm)
:
190mA.
Auxiliary DC output supply
:
Regulated 13.2Vdc for use with PIR,
microwave and shock sensors.
Extension Speaker load
:
8 to 32 Ohms.
Bell
:
500mA.
Strobe
:
500mA.
Alarm bell timer
:
0 to 20 minutes (software
programmable).
Zone type
:
Normally closed loops which activate
when opened or short circuit.
Zone loop current
:
0.76 to 1.03mA.
Zone activation resistance
:
6.9K Ohms (minimum).
Zone loop activation timer
:
0.35 seconds.
Exit timer
:
0 to 99 seconds.
Entry timer
:
0 to 99 seconds.
12.3
Mechanical.
Dimensions
:
240 x 305 x 70mm.
Case material
:
1.2mm thick Mild steel with screw fixing
front
cover.
Colour
:
White.
Weight excluding battery
:
2.9Kg.
12.4
Environmental.
Operating temperature
:
0 to +40
0
C (+32 to +104
0
F).
Storage temperature
:
-20 to +60
0
C (-4 to +172
0
F).
12.5 Cleaning.
DO NOT use strong detergents to clean this control panel. To remove any dirt or grime, wipe with a clean damp cloth ONLY
26
All manuals and user guides at all-guides.com
all-guides.com