9.3
Timers.
9.3.1
Exit Time.
Whilst in Engineer mode enter
followed by the desired exit time in seconds
The exit time may be any 2 digit number from
to
.
9.3.2
Entry Time.
Whilst in Engineer mode enter
followed by the desired entry time in seconds
.
The entry time may be any 2 digit number from
to
.
9.3.3
Bell Delay.
In Engineer mode enter
followed by the desired bell delay in minutes
.
The bell delay will prevent extension speakers and external sirens from operating for the length of time entered.
The bell delay may be programmed as any 2 digit number from
to
.
9.3.4
Bell Time (External Sirens).
In Engineer mode enter
followed by the required bell cut off time in minutes
.
The bell time cut of time may be any 2 digit number from
to
.
9.3.5
Communicator Delay.
A communication delay may be programmed for the Alarm, P.A. and Fire outputs. These outputs will not operate after an
activation, until the communicator delay has expired.
Whilst in Engineer mode enter
followed by a 2 digit time in seconds
.
The communicator delay may be programmed as any 2 digit number from
to
.
9.3.6
Number of Rearms.
In Engineer mode enter
followed by the number of rearms
.
This is the number of times the control panel will rearm itself after activating the external sirens for the bell time programmed.
The number of rearms may be any number from
to
.
9.3.7
Part Set Types.
The three part sets A, B and C may be programmed as timed set, silent timed set or instant set. All three part sets are factory
programmed as timed set.
To alter any of these first enter Engineer mode then press
followed by:
Key
part set A, or
part set B, or
part set C
The letter pressed will be displayed on the keypad.
Then key either
timed set, or
silent timed set, or
instant set
The relevant symbol will be displayed on the remote keypad for a few seconds.
To alter the remaining part sets repeat the above sequence.