EURO 46 Installation Manual
Page: 11
3.2
Important Installation Notes
Ensure wiring is done to the national wiring regulations in the country where the installation is
taking place. In the UK, this is BS 7671 Requirements for electrical installations; IET Wiring
Regulations (17th edition). If in doubt, consult a local qualified electrician.
Ensure that a readily accessible disconnect device incorporated in the premises installation wiring
shall be provided external to the equipment with a contact separation of at least 3,0mm and
connected as closely as possible to the supply. Example: Fused Spur Unit
When fixing external wires, ensure that means are provided in the installation to prevent the SELV
(Safety Electrical Low Voltage) or signal circuits from coming into contact with live parts of the
power supply circuit. Wires shall be fixed near their terminal blocks.
The end of stranded conductor shall not be consolidated by soft soldering at places where the
conductor is subjected to contact pressure. Example: Must not solder ends of wires which are to be
secured in detector and control panel terminal connectors.
On completion of wiring use tie-wraps to prevent any loose wires causing a safety hazard (material
of cables tie shall be rated at least HB or better).
Cables ties and hoses shall be separate for power supply cable and SELV (Safety Electrical Low
Voltage) wirings.
Size of protective bonding conductors: minimum section 1.5mm². Example: Electrical Earth wire
connections.
3.3
Communication ATE Loom
The ATE low power outputs are programmed in the engineer function:
‘CHANGE OUTPUTS->Endstation
PGMs”.
Purple (ATE Output 8: Mains Fail (0052))
Light Grey (ATE Output 10: Test ATS (0064))
White (ATE Output 9: Global Fault 2 (0064))
Black (ATE Output 7: Confirmed Any (0006))
Brown (ATE Output 4: Final Set All (0004))
Red (0V)
Orange (ATE Output 2: HU Device Any (0009))
Yellow (ATE Output 3: Unconfirmed Any (0018))
Green (ATE Output 6: Omit Rearm Any (0017))
Blue (ATE Output 1: Fire (0001))
Purple (ATE Output 5: Tamper Any (0007))
Light Grey (+12V)
White (DO NOT USE)
Black (Line Fault)
Normal Status: 5V
Active Status: 0V
Current: 2mA
The polarity of the ATE outputs can be
inverted from the function 'SITE OPTIONS'
under 'Invert ATE Outputs'.