7.9
Connecting The Output Expander Module with PSU (EURO-PSU)
EURO-PSU
The EURO-PSU is an output
expander that supports 16 relays and
has a built in 2.5A power supply.
The EURO 46 will support up to 2 x
Output Expander Modules. See page:
4.
NOTE: The D2+ terminal must
not be connected.
7.9.1
EURO-PSU Technical Specification
EURO-PSU (Output expander with 16 PGMs and Power Supply)
Supply Voltage
9-15V DC
Current Consumption
25mA, Max 340mA when all outputs are active
PGM1 to PGM16
Programmable
PGM1 to PGM16 Type
Relay, 3A, max 30V
PGM1 to PGM16 Normal State
Changeover NC & NO
PGM1 to PGM16 Active State
Changeover NC & NO
Power Supply Rating
2.0A Continuous and 2.5A in peak when charging battery
Transformer Rating
44VA
Dimensions Metal Box
390 x 205 x 100mm
Dimensions PCB
215 x 125 x 65mm
Front and rear tamper protected with one tamper switch
A 17Ah battery will support a maximum load of 1350mA for a period of 12 hours.
EN50131-1:2006+A1:2009 Installations - Back up battery time = 30hrs providing that a mains fail signal is
reported to the ARC.
A 17Ah battery, will support a maximum load of 497mA for a period of 30 hours.
Installations which are not supported by an ARC mains fail reported signal = 60 hours.
A 17Ah battery, will support a maximum load of 248mA for a period of 60 hours.
EN50131 Certified
Grade 3
7.9.2
Addressing The EURO-PSU (From the Expander)
NOTE
: The addressing is done by headers that represent the address.
For example: If a header is placed on 00, and 9, the address is 9.
If a header is placed on 20, and 3, the address is 23 etc.