EURO 46 Installation Manual
Page: 45
8.4
Assigning Radio Detectors
Press the ‘
AZ
’ and scroll to the input number you wish to
assign a wireless detector to:
Press the ‘’
RESET
’ button on the detector you wish to
assign to that particular input.
Ensure that the jumper on the detector PCB is placed in
the “EU” position.
When the detector is assigned, the
two dots on the display with flash.
8.5
Deleting Radio Detectors
Press the ‘
AZ
’ and scroll to the input number you wish to
delete.
Press the ‘’
CLEAR
’ button. The dots should have cleared,
indicating the detector has been deleted.
8.6
Display the Signal Strength
The radio expander can monitor the signal of the detectors connected onto the system:
Press the ‘
AZ
’ and scroll to the input number you wish to
check. The display will show the input number and two
dots.
Activate the detector and the signal strength will be
displayed (0-99). If it is below 14, use a REPEATER to
boost the signal.
8.7
Assigning Repeaters to the Expander
The radio repeaters act as a ‘Range Expander’ and helps a system scale from smaller commercial
sites to large campuses with several buildings.
NOTE
: Repeaters will use an input from the radio
expander.
Press the ‘
AZ
’ and scroll to the input number you wish to
assign a repeater. To assign the REPEATER to that input,
power the repeater when the input number is displayed,
and one dot will flash to confirm. To remove a repeater
from that input, press
‘CLEAR’
8.8
Supervision Time
The supervision time is the time of monitoring each detector on the radio expander.
Press the ‘
AZ
’ and scroll to the input number you wish to
check. The display will show the input number and two
dots.
With the input number displayed, press the
‘MO’
button to
change the supervision time to (a number will be
displayed, ignore this, just follow the dots).
30 minutes (no dots) / 30 hours (1 dot) / 30 days (2 dots)
AZ
1
0
1
0
AZ
1
0
CLEAR
1
0
AZ
1
0
9
6
AZ
0
AZ
1
0
MO