EURO 46 Installation Manual
Page: 48
9.1
Connecting to the Upload/Download Software
The EURO 46 control panel can be programmed by the LCD menu or the UDL InSite Software
provided free of charge. It can be downloaded from
http://www.pyronix.com/pyronix-downloads.php
.
The connection between control panel and UDL software can be done in the following ways:
9.1.1
Serial Connection (RS232)
1.
Enter the Engineer menu (code 1111)
2.
Scroll the menu until the “SET UP DOWNLOADING”
3.
Choose RS-232 in the “Download by” option
9.1.2
On InSite UDL software from a PC
1.
To setup the COM port associated to “modem” open the software, click on “Configuration”, -
choose “Modem Settings” and select “RS-232” option
2.
Make sure that the serial COM used by UDL is the same set in the PC
3.
Make sure that the UDL Graphic User Interface has the RS-232 icon green colored and glowing
4.
Click on “Roving Dial Customer”
5.
Set “Dial Mode” field to “RS-232”
6.
Enter the Engineer code in the “Engineer Code” field
7.
Click on “Dial”
8.
If connection is successful, the RS-232 icon will become blue
NOTE:
If a Site Name is set up on the panel the UDL Site Name must be the same otherwise the
connection will not be possible.
9.1.3
Modem Connection (DIGI PSTN)
Make sure that the panel and the modem on the PC where UDL is installed are connected to a
suitable PSTN line.
On the Panel
1.
Enter the Engineer Menu (code 1111)
2.
Scroll the menu until the “SET UP DOWNLOADING”
3.
Choose Modem in the “Download by” option
On InSite UDL software from a PC
1. To setup the COM port associated to “modem” open the software, click on “Configuration”,
choose “Modem Settings” and select “MODEM” option
2. Verify that COM port associated to “Modem” in the UDL is the same set in the PC
3. Verify that the modem Icon is green and glowing in the software Graphic User Interface
4. In the “Configurations” menu choose the “Modem Type” from the drop down menu. This is the
modem connected to the PC and used to call the panel
5. Press “Load Default String” to program the right initialization string for the selected modem
6. Click on “Force Dial customer”
7. Set “Dial Mode” field to “MODEM”