Low Total Cost of Ownership 

Long life cycles reduces cost of average life expectancy; 

High energy efficiency reduces procurement costs; 

Small size, it need less space for the same capacity; 

Maintenance-free brings lower cost. 

High Adaptability to Environment 

The operation temperature range is from -10

 to 50

It is suitable for frequent outages and no memory effect; 

It is designed for dustproof structure. 

Intelligent Battery Management System 

Each single module is designed for load distribution; 

Intelligent  design  makes  charging  mode  can  be  adjusted 
according to battery charging status automatically ; 

The  lossless  and  equalization  charging  technology  makes 
charging current adjustable; 

The  central  processor  design,  cooperates  with  multiple 
monitoring modules, can fully monitoring battery information. 

High Security 

The battery passed drop and collision test; 

The  battery  will  be  not  burning  or  explosion  in  case  of 
acupuncture, baking and other extreme statues; 

Multiple safety protection, it provides protection function in high 
current, voltage, or temperature. 

 

Real-time info gather and upload  

  

Charge ending protection 

  

Discharge ending protection 

  

High and low temperature alarms 
and protection  

  

Charge over voltage, over current 
alarms and protection  

  

Discharge low voltage alarm and 
protection  

  

Charge over current alarm and 
protection  

  

Discharge over current alarms and 
protection  

  

Reverse alarm and protection  

  

Short-circuit alarm and protection  

  

Protection auto recovery  

  

Intelligent charging and discharging 
management  

  

Lossless balanced management  

  

Webmaster remote monitoring  

  

Fault Logging recording  

  

Online upgrade system  

  

Lightning protection design  

 

  

Note:  “

    

 means it has this function; 

-

” means no such 

function;

 

“   ”

 

means that this function is optional.

 

Comprehensive advantages

 

System Management Function 

Basic Parameters 

Extra2000 

Life (25

/77

          10 years 

Life (40

/122

           8 years 

Life Cycles (80% DOD, 
25

/77

>

4000 

Maintenance 

Free in quality guarantee 

period 

Backup Duration (Average 
Power 500W

 

          

5h 

Storage Time

25

/77

 

6 Months power off 

Operation Temperature 

-10

~50

-14

~122

 

Storage Temperature 

-40

~80

-40

~176

 

Seismic Standard 

GR-1089 

Transport Standard 

UN 3090 

EMC Standard 

IEC 61000

EN 55022 

Environmental Standard 

GB/T 2423 

The Authentication Level 

TUV,CE,CCC,TLC 

Life Cycle Curve 

-20~60

1C Rate Discharge Curve 

For more information please contact Pylon Technologies Co., Ltd. 

www.pylontech.com.cn 

 

Summary of Contents for Extra 2000

Page 1: ...Extra 2000 Lithium Iron Phosphate Battery Backup Product Manual Information Version 1 2...

Page 2: ...owners of tradenames this manual does not confer the license or right by the reader to use any mark appeared on this manual in any way This product accord with the design requirements of environmental...

Page 3: ...parameters and others of Extra 2000 Chapter 3 Installation and Collocation Product installation network usage and requires attention in installation process of Extra 2000 Chapter 4 Maintenance and Tr...

Page 4: ...n Function 5 2 3 Charge Parameters 5 2 4 Discharge Parameters 6 3 Installation and Configuration 7 3 1 Installation Preparation 7 3 1 1 Environmental Requirements 8 3 1 2 Tools and Information 8 3 1 3...

Page 5: ...on Process 9 Figure 3 2 Schematic Device Fixed to the Cabinet 13 Figure 3 3 Multiple Batteries in Parallel Power Line Connection Diagram 14 Figure 3 4 Connection Interface between Battery and Load Equ...

Page 6: ...n 3 Table 2 3 ADD Switch 4 Table 2 4 LED Indicators Instructions 4 Table 2 5 Protection Function Parameters 6 Table 2 6 Charging Parameters 7 Table 2 7 Discharging Parameters 7 Table 3 1 Tools and Met...

Page 7: ...nterrupted the battery provides energy for user equipment Multiple batteries can be connected for larger capacity in parallel for longer duration backup requirements 1 2 Product Features Extra 2000 pr...

Page 8: ...ng temperature range is from 10 to 55 with excellent discharge performance and cycle life in high temperature Small size and light weight standard of 19 inch embedded design comfortable installation a...

Page 9: ...ion Interface 3 4 RS485 port No 3 Figure 2 1 when using multiple batteries in parallel cascade each RS485 interface information of other packs can be checked from the main pack The definition of main...

Page 10: ...inary coded bits 1 is low 4 is high Table 2 3 Example 1 4 address coding 5 8 address and so on If several Extra products cascading multiple network devices the address encoding 1 is the main battery o...

Page 11: ...0 25s off 3 75 seconds flash 2 0 5s light 0 5s off flash 3 0 5s light 1 5s off 2 2 Battery Management System BMS 2 2 1 Voltage Protection Low Voltage Protection in Discharge When discharging the prot...

Page 12: ...mum charge current limit value see Table 2 6 Charging Parameters Discharging Current Limit To protect the load equipment working Extra 2000 sets the maximum discharge current limit see Table 2 7 disch...

Page 13: ...2000 product sets the maximum charge current to protect the power supply and load equipments Table 2 6 Charging Parameters Model Voltage Range in Charging Current Limit in Charging Min Max Max Extra 2...

Page 14: ...rcuit under 48V connected to the external power supply system must meet following criteria defined in IEC60950 SELV Requirements If operation of the power system is in cabinet it must ensure that the...

Page 15: ...irements Ambient Temperature 10 55 Relative Humidity 5 93 RH Altitude Under 4000m Working environment No conductive dust and corrosive gas 3 1 2 Tools and Information Hardware Tools and instruments ar...

Page 16: ...ts to the user device please check To check the user whether the device with DC backup power interface and whether the output voltage electrical equipment meets the requirements in voltage range of Ta...

Page 17: ...tems placed next to battery 3 1 4 Unpacking When equipments arrive at the installation site before unpacking check whether the box appearance is intact or not and calculate total number according to f...

Page 18: ...ade 5 Communication Interface Collection 6 Power Supply 3 2 1 Mechanical Installation Before installation disconnect the entire device s power directly contact and recognizing that the battery is turn...

Page 19: ...re connecting power and landing using multimeter to measure cable continuity short circuit and confirmed anode and cathode and make the cable labels Measuring methods Cable continuity Select buzz file...

Page 20: ...er connector from top to bottom are negative and positive The 2 interfaces have same function when multiple batteries in parallel using parallel power cable to connect each battery After parallel any...

Page 21: ...Battery and Switch Power This installation method can be used when switching power supply to loads Installing the battery power cord priority access battery interface first if switching power supply...

Page 22: ...tinue with this step If not using the net management this step is not required To check network management information of all batteries through one battery please parallel each battery through RS485 i...

Page 23: ...interface with ADD Address is 1 6 Powering on Device After completing these steps turn on power to the entire system to activate the battery installation completed Note After power on if found ALM in...

Page 24: ...jor Alarm and Protection Statue Alarm Category Alarm Indication Processing Charging Cell Over voltage ALM Lighting Stop charging and find the cause Over current ALM Lighting Stop charging and find the...

Page 25: ...Alarm ALM Flashing Stop Discharging 4 2 Common Fault Analysis and Solutions Common fault analysis and solutions shown in table 4 3 Table 4 3 Common Faults and Solutions Number Fault Symptom Reason An...

Page 26: ...osphate backup solutions focus on this type of problems Pylontech put forward integrated high performance service of backup power protection for operators without occupying extra room space Some scena...

Page 27: ...upload Charge ending protection Discharge ending protection High and low temperature alarms and protection Charge over voltage over current alarms and protection Discharge low voltage alarm and protec...