CONQUEST
®
WATER HEATER
33
PV500-71 02/16
10.5 Control System Menus
The control display has multiple access levels. System critical settings will not be available for adjustment. The
settings which can be adjusted by the user will display UP and DOWN adjustment arrows on the right side of the
display screen. These programmable menu items are located in the Control System Menu.
To access the Control System Menu:
1. Press and hold the HOME button for 3 seconds.
2. Touch NEXT ITEM to navigate to the next menu. Touch ITEM BACK to go reverse.
3. Touch ENTER to enter and change user accessible menu item settings in the control system menus.
4. Most settings are in the USER access level. Other setting will be located in the INSTaller or ADVanced access
level depending on the necessity for field adjustment. See Using the Tool Box Menu for details.
Control System Menu Descriptions
Menu Description
SETUP
Displays and modifies the temperature control set points for the burner, integral tank circulator
and the SANI functions
SOURCE
Displays many factory programmed settings for this product. The settings which can be
adjusted by the user will be indicated by the appearance of the up and down adjustment arrows
MONITOR
Displays operational information such as water and vent temperatures, hours of operation, and
number of cycles
TIME
Sets the time, day and year. Setting the time clock is necessary when using the scheduled
setback
SCHEDULE
Allows the user to create a schedule for reducing the water heater set point when a building is
unoccupied for a period of time
NETWORK
Displays and modifies parameters for creating a Modbus communication connection with the
water heater
OVERRIDE
Allows the user to assume manual control of the burner operation and pumps
TOOLBOX
Displays alarm message history. Changes User access level and reset to factory default
settings
10.6 Changing The Operating Set Point (USER Level Access)
The water Conquest water heater operates to satisfy the stored water temperature set point of the EOS control. The
value of the controls’ set point is the desired stored tank water temperature. The unit ships with a factory set point of
120
⁰
F.
Although the set point can be displayed in the VIEW menu, it is necessary to enter the CONTROL SYSTEM MENU
in order to make adjustments to the water heater set point and other operational parameters.
To Change the Water Heater Set Point
1. From the View Menu, press and hold the HOME button for 3 seconds to enter the Control System Menu. The
first menu displayed is the SETUP Menu.
2. Touch the ENTER button to display the SETPOINT Menu.
3. Adjust the set point value using the UP and DOWN arrow buttons.
4. To save the new value, touch the NEXT ITEM or ITEM BACK buttons or exit the menu by pressing the HOME
button.