NTS/NTX User Guide

Before Installation

•  The control valve, fittings and/or bypass are designed to accommodate minor plumbing 

misalignment but are not designed to support the weight of a system or the plumbing.

•  Do not use petroleum jelly, oils, other hydrocarbon lubricants or spray silicone anywhere. A 

silicon lubricant may be used on the black o-rings but it is not necessary.

•  Do not use pipe dope or other sealants on threads. Thread seal tape is the preferred sealant 

but is not necessary on the nut connection or caps because of o-ring seals.

•  All plumbing should be done in accordance with local plumbing codes. 

Avoid getting primer and solvent cement on filter system.

•  Install grounding strap on metal pipes if required.
•  Ensure the system is protected against high pressure and extreme temperatures.

WARNINGS

Locate Water Treatment Equipment Correctly

Select the location of your neutraliser with care. Various conditions which contribute to proper 
location are as follows:
• 

Locate in correct relationship to other water conditioning equipment. Contact Puretec for 
assistance.

• 

Locate the neutraliser in the supply line BEFORE the water heater. 

• 

DO NOT install the neutraliser in a location with temperatures below 0

°

C or above 40

°

C. 

Temperatures outside these limits may cause permanent damage and will also void the 
warranty.

• 

Protect from pressure vacuum with a suitable vacuum breaker.

• 

For point of entry installations an approved backflow prevention device must be installed. 

• 

Where line pressure exceeds 500 kPa, an approved pressure limiting device must be 
installed to comply with Australian & New Zealand Plumbing Standards. (Ref. AS/NZS 
3500.1:2021, Clause 3.3.4).

• 

DO NOT install where water hammer conditions may occur without installing an arrestor.

• 

Allow sufficient space for installation and easy servicing.

Facts to Remember While Planning Your Installation:

• 

All installation procedures MUST conform to local plumbing codes.

• 

If lawn sprinklers, a swimming pool, or geothermal heating/cooling or water for other 
devices/activities are to be treated by the neutraliser, a larger model MUST be selected to 
accommodate the higher flow/volume. Contact Puretec for assistance.

Summary of Contents for NTS Series

Page 1: ...rect operation installation it is essential to observe these instructions JAN2022 WMTS103 2016 Cert No WM 74593 Australian Certification Services User Guide Neutralising Water Treatment Systems NTS NTX Series ...

Page 2: ...r types of water supply please contact your local Puretec dealer Puretec Treatment Systems are designed to run economically for many years dependent on the initial installation and periodic maintenance Flush system for 5 minutes or more after any period of non use more than 2 weeks Note For point of entry installations an approved dual check backflow prevention device must be installed When line p...

Page 3: ...an and if not replaced will eventually fail Failure can happen early due to unforeseen circumstances To avoid possible property damage this product should be regularly examined for leakage and or deterioration and replaced when necessary We strongly recommend that a drain pan plumbed to an appropriate drain or outfitted with a leak detector be used in those applications where any leakage could cau...

Page 4: ...hing is required NTX systems have the added benefit of a blending mixing valve to further adjust the pH of the water IMPORTANT NOTE Since the neutraliser media dissolves as it elevates pH level it will increase the hardness of your water Installation of a water softener may be necessary if the hardness becomes a problem Before Installation Professional Installation Required Installation requires s...

Page 5: ... follows Locate in correct relationship to other water conditioning equipment Contact Puretec for assistance Locate the neutraliser in the supply line BEFORE the water heater DO NOT install the neutraliser in a location with temperatures below 0 C or above 40 C Temperatures outside these limits may cause permanent damage and will also void the warranty Protect from pressure vacuum with a suitable ...

Page 6: ...l Copyright Puretec Pty Ltd 2022 NTS Exploded Diagram Fig 1 NTS Exploded Diagram Spanner Pressure Tank UV Shield Riser Pipe pre installed In Out Head with Fill Port Elbow Adaptors Bypass Valve Optional Sold Separately Pressure Tank ...

Page 7: ... X NTS NTX User Guide 1 Media Kit WTM2000 15L Neutrasafe Neutralising Media 15L 1 NTS1000 Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 178 mm W x 889 mm H Service Flow Rate 15 Lpm Max Flow Rate 40 Lpm Vessel Media Filling Order 1st 1 x WTM2000...

Page 8: ... NTS X NTS NTX User Guide 1 Media Kit WTM2000 15L Neutrasafe Neutralising Media 15L 2 NTS2000 Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 229 mm W x 1350 mm H Service Flow Rate 20 Lpm Max Flow Rate 70 Lpm Vessel Media Filling Order 1st 2 x WT...

Page 9: ...X NTS NTX User Guide 1 Media Kit WTM2000 15L Neutrasafe Neutralising Media 15L 3 NTS3000 Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 254 mm W x 1500 mm H Service Flow Rate 30 Lpm Max Flow Rate 80 Lpm Vessel Media Filling Order 1st 3 x WTM2000...

Page 10: ...G NTS X NTS NTX User Guide 1 Media Kit WTM2000 15L Neutrasafe Neutralising Media 15L 4 NTS4000 Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 305 mm W x 1470 mm H Service Flow Rate 40 Lpm Max Flow Rate 90 Lpm Vessel Media Filling Order 1st 4 x W...

Page 11: ...unnel 1 UG NTS X NTS NTX User Guide 1 Media Kit WTM2000 15L Neutrasafe Neutralising Media 15L 8 NTS70 C Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 406 mm W x 1790 mm H Service Flow Rate 70 Lpm Max Flow Rate 120 Lpm Vessel Media Filling Order...

Page 12: ...ia Funnel 1 UG NTS X NTS NTX User Guide 1 Media Kit WTM2000 15L Neutrasafe Neutralising Media 15L 15 NTS120 C Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 533 mm W x 1850 mm H Service Flow Rate 100 Lpm Max Flow Rate 150 Lpm Vessel Media Fillin...

Page 13: ...2 NTS NTX User Guide NTX Exploded Diagram Fig 2 NTX Exploded Diagram Pressure Tank Spanner Pressure Tank UV Shield Riser Pipe pre installed In Out Head with Fill Port Elbow Adaptors Bypass Valve Optional Sold Separately Blending Valve ...

Page 14: ...safe Neutralising Media 15L 2 Blending Valve Kit WTV5050 Blending Valve User Guide 1 NTX2000 Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 229 mm W x 1350 mm H Service Flow Rate 20 Lpm Max Flow Rate 70 Lpm Vessel Media Filling Order 1st 2nd 3rd...

Page 15: ...Neutralising Media 15L 2 Blending Valve Kit WTV5050 Blending Valve User Guide 1 NTX3000 Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 254 mm W x 1500 mm H Service Flow Rate 30 Lpm Max Flow Rate 80 Lpm Vessel Media Filling Order 1st 2nd 3rd 1 x ...

Page 16: ...asafe Neutralising Media 15L 3 Blending Valve Kit WTV5050 Blending Valve User Guide 1 NTX4000 Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 305 mm W x 1470 mm H Service Flow Rate 40 Lpm Max Flow Rate 90 Lpm Vessel Media Filling Order 1st 2nd 3r...

Page 17: ...15L Neutrasafe Neutralising Media 15L 6 Blending Valve Kit WTV5050 Blending Valve User Guide 1 NTX70 C Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 406 mm W x 1790 mm H Service Flow Rate 70 Lpm Max Flow Rate 120 Lpm Vessel Media Filling Order ...

Page 18: ...2000 15L Neutrasafe Neutralising Media 15L 8 Blending Valve Kit WTV5050 Blending Valve User Guide 1 NTX120 C Model Information System Inclusions Kits Components Specifications Operating Pressure Min Max 138 862 kPa Operating Temperature Min Max 0 40 C protect from freezing Inlet outlet Connection 1 Dimensions 533 mm W x 1850 mm H Service Flow Rate 100 Lpm Max Flow Rate 150 Lpm Vessel Media Filling...

Page 19: ...___ ppm mg L Sodium ___________ ppm mg L 130 0 3 0 1 7 275 404 121 96 Customer Service Helpline 1300 140 140 AU 0800 130 140 NZ Unpack the Equipment Ensure all parts are present and have not been damaged in transport See specific model specifications for complete kit component details 1 For correct operati on installa tion it is essenti al to observ e these instruc tions JUN2018 WMTS103 2016 Cert ...

Page 20: ...ater heater Temperatures above 43 3 C 110 F will damage the system and void the warranty 5 DO NOT install the treatment in a location where freezing temperatures occur Freezing may cause permanent damage and will also void the warranty 6 DO NOT install where water hammer conditions may occur without installing an arrestor 7 Allow sufficient space around the installation for easy servicing Installi...

Page 21: ...ll the plastic fittings by turning the knob counterclockwise Connect the bypass assembly followed by the plastic fittings Hand tighten the knobs do not overtighten Refer to Page 13 for bypass operation Optional Install MP100B PL05MP1 on the outlet to prevent an excess media from coming through the line 5 ...

Page 22: ...ing the line You may have been supplied with more media than required retain this for future replenishing 3 Adjust the bypass to allow water flow refer to Page 13 and turn the water supply back on 4 The water will initially be milky white in appearance Flush the water through the system until all the air in the lines is expelled or when the water runs clear 5 Installation is now complete and your ...

Page 23: ... the supply is exhausted No extra water is required when topping up the media level An easy way to determine if the neutraliser requires media replenishment is to place a mark on the outside of the unit at the maximum level of the media when first installed Every 2 3 months check the level by shining a light through the tank and compare the current level to the maximum If you are unable to see thr...

Page 24: ...n hose 4 Reconnect the fill port head and inlet outlet connections IMPORTANT SERVICING NOTE Under normal circumstances removal of the fill port head assembly should not be required However if it must be removed disconnect the plumbing attached to the bypass valve first Then rotate the fill port head assembly to the left or counter clockwise Before attempting any disassembly pressure should be reli...

Page 25: ...TX User Guide SUPPLY WATER ENTERS NO WATER EXITS TREATED WATER EXITS SUPPLY WATER ENTERS SUPPLY WATER EXITS SUPPLY WATER ENTERS Normal Operation Bypass Operation Shut Off Mode Bypass Valve Operation Optional Accessory Bypass Valve Operation ...

Page 26: ...pon installation 1 Make sure bypass valve is closed 2 Test water or have it tested via third party If high hardness or total dissolved solids TDS seek alternate means of treatment such as feeding a solution of soda ash or caustic soda C Neutraliser fails to increase pH after being in service 1 Check filter bed for cementing or channelling Break channelling or cementing with stiff rod or tubing D E...

Page 27: ...tec to ensure product was not incorrectly used installed or claimed False and incorrect claims will be pursued at Puretec s discretion including chargeable inspection and labour costs incurred Warranty Australia This warranty is given by Puretec Pty Ltd ABN 44 164 806 688 37 43 Brodie Road Lonsdale SA 5160 telephone no 1300 140 140 and email at sales puretec com au This warranty is provided in add...

Page 28: ......

Reviews: