9
Copyright © Puretec Pty Ltd 2022
NTS/NTX User Guide
NTS3000 Model Information
Kit Type
Part no.
Description
Qty
Vessel & Instruction
Kit
WTP2280
Pressure Tank with Base (10x54)
1
WTV3030
Pressure Tank UV Collar Shield
1
WTD2130
Riser Pipe & Distributor (pre-installed)
1.8m
WTV1010
In/Out Head with Fill Port
1
WTV5070
1" Elbow Adaptors (pack of 2)
1
WTV5180
Spanner
1
WTV1500
Media Funnel
1
UG-NTS/X
NTS/NTX User Guide
1
Media Kit
WTM2000-15L
Neutrasafe Neutralising Media 15L
3
NTS3000 Model Information
System Inclusions - Kits & Components
Specifications
Operating Pressure Min/Max*:
138 - 862 kPa
Operating Temperature Min/Max:
0 - 40 °C (protect from freezing)
Inlet/outlet Connection:
1"
Dimensions:
254 mm (W) x 1500 mm (H)
Service Flow Rate:
30 Lpm
Max Flow Rate:
80 Lpm
Vessel Media Filling Order
1st
3 x WTM2000-15L
* Where line pressure exceeds 500 kPa, an approved pressure limiting device must be installed to comply with
Australian & New Zealand Plumbing Standards. (Ref. AS/NZS 3500.1:2021, Clause 3.3.4).
Summary of Contents for NTS Series