Altec AIR
P8400W Air-dryer User’s Guide
Page 19 of 110
P017585 – Rev. A
6.5.16.2
Turn the knob until
the reading on the
pressure gauge is
50
PSI
.
6.5.16.3
Push the knob in to
lock.
6.5.17
Let the dryer run until the
Humidity drops under 2% on both
System 1 and System 2 (may take
up to 15 minutes).
NOTE
: Press
RESET
if either System goes into
SHUTDOWN.
6.5.18
Turn the dryer
OFF
.