Summary of Contents for 580.52650

Page 1: ...Owner s Manual Manual del Propietario DEHUMIDIFIER DESHUMIDIFICADOR Model Modelo 580 52650 Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com ...

Page 2: ...ith the product Sears will repair the Dehumidifier free of charge if defective in materials or workmanship FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when this Dehumidifier is operated and maintained according to owner s instructions furnished with the product Sears will repair the sealed refrigeration system consisting of refrigerant connecting...

Page 3: ...ove any prong from the power cord Grounding type wall receptacle Do not under any circumstances cut remove or bypass the grounding prong from this plug Power supply cord with 3 prong grounding plug ELECTRICAL INFORMATION The complete electrical rating of your new dehumidifier is stated on the serial plate Refer to the rating when checking the electrical requirements Be sure the dehumidifier is pro...

Page 4: ...ssible shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacle installed by a qualified...

Page 5: ...e the risk of fire electric shock or injury to persons read the important SAFETY instructions section before operating this appliance 1 CONTROL PANEL 2 GRILLE FRONT 3 POWER CORD 4 CABINET 5 AIR FILTER 6 WATER BUCKET 2 3 4 5 5 ...

Page 6: ...on to set the amount of time you want the unit to run The Timer can be set for Constant 8 hour 4 hour or 2 hour When Timer button is pressed the Timer indicatorlights shift as follows Constant 2 hr 4 hr 8 hr Constant TO OPERATE THE DEHUMIDIFIER 1 Plug the power cord into an electrical outlet Press the power button 2 Set the HumidityControl anywhere between 30 RH and 70 RH for normal operation If y...

Page 7: ...st occurs the unit will cycle on and off This is normal Unplug the unit or turn the unit off until the frost melts and the room temperature rises DEFROST CONTROL When the defrost control senses frost build up on the evaporator coil it will automatically shut off the compressor The fan will continue to run to draw air across the coil and melt the frost When the coil is defrosted the compressor will...

Page 8: ...a large sink or tub When finished replace it properly NOTE To replace the bucket properly make sure the slots on the back of bucket are positioned correctly Place the dehumidifier directly over drain The bucket has a threaded hose connection which can be left open Drill a 1 4 6 4ram to 1 2 13mm hole in the center of the hose connection Once opened the hose connection will continually drain water f...

Page 9: ...se and let the filter dry before replacing it CLEANING INSIDE THE UNIT After removing the air filter clean the coil on the inside with a soft brush to remove any soft and wet soil NOTE Do not allow water to enter the electrical machine compartment through the circular opening behind the coil Do not spray the coil with a hose GENERAL CLEANING Dust the front grille and the side panels with a soft br...

Page 10: ...fier Press the _ Humidity Control button to lower the humidity Check that all doors windows and other openings are securely closed Instalt the dehumidifier away from the dryer The dryer should be vented to the outside The unit will not operate satisfactorily if the room temperature is below 65 F 18 C Check with your dealer to see if the capacity is adequate Close all doors and windows to the outsi...

Page 11: ...00A30003C 6500A90002A 3090A10001J 4994A20012A 6871A10016A 0CZZA20001F DESCRIPTION BASE ASSY WELD HOUSINGASSY SINGLE DRAIN PAN SWITCH ASSY MICRO SENSOR CABINET CONTROLBOX SINGLE PWB ASSY MAIN CAPACITOR POS N0 PARTNO 10 A 4H00442J 11 A 6631AQ3132U 12 A 5230AD3005A 13 A 6411A20001L 14 A 3530A10006F 15 A 3831A20016A 16 A 3551A30030A 17 A 4838A20005A 18 A 3096AR2871H DESCRIPTION CLAMP CAPACITOR CONNECT...

Page 12: ... the Kenmore part number not the position number CYCLE PARTS POS NO PART NO DESCRIPTION 1 B 4681A20034C 2 B 5900AD2013A 3 B 4H02861A 4 B 5403A20027D 5 B 5421A20046C MOTOR ASSY SINGLE FAN ASSY PROPELLER FAN NUT CONDENSER ASSY EVAPORATOR ASSY 12 ...

Page 13: ...ON 1 C 4H00947A 2 C 3550 CL001D 3 C 4970U L002A 4 C 6750U L035A 5 C 4986U L001B 6 C 5416A90003A 7 C 1NHA0801206 8 C 4810AR4155A 9 C 4830A30005A 10 C 5211A20237A 11 C 5211A10070B 12 C 5211A10085B 13 C 3Q35015Q NUT TERMINAL COVER TERMINAL COVER SPRING O L P O L P GASKET COMPRESSOR NUT HEXAGON I BRACKET WASHER BUSHING TUBE ASSY SUCTION TUBE ASSY DISCHARGE TUBE ASSY CAPILLARY THERMISTOR ASSY 13 ...