background image

Write the model and serial 
numbers here:

Model # _________________

Serial # _________________

You can find them on a label on 
the back of the dehumidifier.

GE is a trademark of the General Electric Company. Manufactured under trademark license.

OWNER’S MANUAL

DEHUMIDIFIER

49-5000443   Rev. 1   11-19   GEA

ADHB35

ADHB50

SAFETY INFORMATION

  . . . . . . . . .3

OPERATING INSTRUCTIONS

Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installation Instructions . . . . . . . . . . . . . . . . .5
How the Dehumidifier Operates  . . . . . . . . .6
Automatic Defrost . . . . . . . . . . . . . . . . . . . . .6
Choosing a Location  . . . . . . . . . . . . . . . . . . .6
Removing Collected Water  . . . . . . . . . . . . .7
Water Level . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Bucket Operation . . . . . . . . . . . . . . . . . . . . . .7

CARE AND CLEANING

Grille and Case . . . . . . . . . . . . . . . . . . . . . . . .8
Water Bucket  . . . . . . . . . . . . . . . . . . . . . . . . .8
Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

TROUBLESHOOTING TIPS

 . . . . . . .9

ELECTRIC SCHEMATIC  

DIAGRAM

  . . . . . . . . . . . . . . . . . . . . . . . . . 10

CONSUMER SUPPORT

Limited Warranty . . . . . . . . . . . . . . . . . . . . . 11
Consumer Support . . . . . . . . . . . . . . . . . . . . 12

ENGLISH/ESPAÑOL

Summary of Contents for ADHB35

Page 1: ...UMIDIFIER 49 5000443 Rev 1 11 19 GEA ADHB35 ADHB50 SAFETY INFORMATION 3 OPERATING INSTRUCTIONS Controls 4 Installation Instructions 5 How the Dehumidifier Operates 6 Automatic Defrost 6 Choosing a Location 6 Removing Collected Water 7 Water Level 7 Bucket Operation 7 CARE AND CLEANING Grille and Case 8 Water Bucket 8 Air Filter 8 TROUBLESHOOTING TIPS 9 ELECTRIC SCHEMATIC DIAGRAM 10 CONSUMER SUPPOR...

Page 2: ...es into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your GE appliance now online Helpful websites and phone numbers are available in the Consumer Support section of this Owner s Manual You may also mail in the pre printed registratio...

Page 3: ...removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do Ŷ R QRW XVH RXWGRRUV Ŷ 7KLV GHKXPLGLILHU LV LQWHQGHG IRU LQGRRU UHVLGHQWLDO DSSOLFDWLRQV RQO 7KLV GHKXPLGLILHU VKRXOG QRW EH used for commercial or industrial applications Ŷ 7KHVH 5 HKXPLGLILHU 6 VWHPV UHTXLUH contractors and technicians to use tool...

Page 4: ...eaning section 6 Delay Off While the dehumidifier is operating press the Delay button 3UHVV WKH 8S UURZ RZQ UURZ EXWWRQV WR VHOHFW WKH QXPEHU of hours you want the dehumidifier to continue to operate before turning Off NOTE After displaying the time the Display will revert to showing the current humidity after 5 seconds have passed 3UHVVLQJ WKH HOD EXWWRQ ZLOO GLVSOD WKH QXPEHU RI KRXUV OHIW on th...

Page 5: ...ters 1 Remove the 4 casters from the bag taped to the inside of the water bucket lid 2 Carefully lay the dehumidifier down on it s front or back 3 Following the arrows on the base slide the 4 casters into place 4 Place the unit upright and wait 1 hour before use Installation Instructions OPERATING INSTRUCTIONS Dehumidifier is on it s front ...

Page 6: ... WR SUHYHQW PRLVWXUH GDPDJH anywhere books or valuables are stored Ŷ 8VH WKH GHKXPLGLILHU LQ D EDVHPHQW WR KHOS SUHYHQW moisture damage Ŷ 7KH GHKXPLGLILHU PXVW EH RSHUDWHG LQ DQ HQFORVHG DUHD to be most effective Ŷ ORVH DOO GRRUV ZLQGRZV DQG RWKHU RXWVLGH RSHQLQJV WR the room NOTE 7KH GHKXPLGLILHU KDV UROOHUV WR DLG SODFHPHQW but it should only be rolled on smooth flat surfaces Do not attempt to r...

Page 7: ...hebucketfromthefrontoftheunit 2 Openthedraincoveronthesideoftheunit 3 Threadagardenhose notsupplied ontothenozzle cutto length andleadittothefloordrain 4 Replacethebucketintheunit NOTE Thebucketmustbeinplaceandsecurelyseatedfor thedehumidifiertooperate Always make sure the water bucket is locked into place on the dehumidifier Water Level 7KH GHKXPLGLILHU ZLOO WXUQ RII DXWRPDWLFDOO ZKHQ WKH EXFNHW ...

Page 8: ...r CAUTION 2 127 RSHUDWH WKH GHKXPLGLILHU without a filter because dirt and lint will clog it and reduce performance Grille and Case To clean the case 8VH ZDWHU DQG D PLOG GHWHUJHQW R QRW XVH bleach or abrasives To clean the top or rear grille 8VH D YDFXXP DWWDFKPHQW RU EUXVK Water Bucket To clean Every few weeks clean the bucket to prevent growth of PROG PLOGHZ DQG EDFWHULD 3DUWLDOO ILOO WKH EXFNH...

Page 9: ... RU DW 16 1RQVWRS IRU PD LPXP dehumidification Doors and windows may not be closed tightly Check that all doors windows and other openings are securely closed Clothes dryer may be blowing moisure laden air into the room QVWDOO WKH GHKXPLGLILHU DZD IURP WKH G HU 7KH GU HU should be vented to the outside Room temperature is too low Moisture removal is best at higher room temperatures RZHU URRP WHPSH...

Page 10: ...W QRWLFH 3OHDVH UHIHU WR WKH FRUUHFW RQH RQ WKH XQLW G GREEN BL BLUE BR BROWN B BLACK Y YELLOW W WHITE R RED NOTE THE PART MAY NOT BE USED 1 BECAUSE OF DIFFERENT COMPRESSOR 1 C M 1 R 0R BL M G Y G K4 3 4 FAN CAPACITOR B HERM C W R S B W BL B BR COMPRESSOR PROTECTOR HEAT main board TRANSFORMER UI board water full board wifi module ...

Page 11: ... to provide reasonable and necessary maintenance Replacement of house fuses or resetting of circuit breakers DLOXUH GXH WR FRUURVLRQ Damage to the product caused by improper power supply voltage accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this product Damage caused after delivery What Will Not Cover For The Period Of Will Replace One Year ...

Page 12: ... DUH DYDLODEOH ZKLOH RXU warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com extended warranty RU FDOO GXULQJ QRUPDO business hours Remote Connectivity RU DVVLVWDQFH ZLWK ZLUHOHVV QHWZRUN FRQQHFWLYLW IRU PRGHOV ZLWK UHPRWH HQDEOH YLVLW RXU ZHEVLWH DW GEAppliances com connect RU FDOO LQ WKH 8...

Page 13: ...9 5000443 Rev 1 11 19 GEA ADHB35 ADHB50 INFORMACIÓN DE SEGURIDAD 3 INSTRUCCIONES DE OPERACIÓN Controles 4 Instrucciones de instalación 5 Cómo funciona el deshumedificador 6 Descongelado automático 6 Selección del lugar adecuad 6 Cómo desechar el agua acumulada 7 Nivel de agua 7 Funcionamiento del Balde 7 CUIDADO Y LIMPIEZA Rejilla y gabinete 8 Tanque de agua 8 Filtre de aire 8 CONSEJOS PARA LA SOL...

Page 14: ...s y creemos que usted también Entre otras cosas el registro de su electrodoméstico asegura que podamos entregarle información importante del producto y detalles de la garantía cuando los necesite Registre su electrodoméstico GE ahora a través de Internet Sitios Web y números telefónicos útiles están disponibles en la sección de Soporte para el Consumidor de este Manual del Propietario También pued...

Page 15: ...LRQHV UHVLGHQFLDOHV GH LQWHULRU 1R GHEH XVDUVH SDUD aplicaciones comerciales ni industriales Ŷ VWRV 6LVWHPDV HVKXPHGLILFDGRUHV 5 UHTXLHUHQ que los contratistas y técnicos utilicen herramientas equipamiento y normas de seguridad aprobadas para VX XVR FRQ HVWH UHIULJHUDQWH 12 XWLOLFH HTXLSDPLHQWR certificado sólo para refrigerante R22 Ŷ VWH HOHFWURGRPpVWLFR SXHGH VHU XVDGR SRU SHUVRQDV FRQ capacidad...

Page 16: ... funcionamiento presione el botón Delay Retraso 3UHVLRQH ORV ERWRQHV 8S UURZ OHFKD DFLD UULED RZQ UURZ Flecha Hacia Abajo para seleccionar la cantidad de horas que desea que el deshumidificador continúe funcionando antes de apagar el mismo NOTA XHJR GH H KLELU HO WLHPSR OD SDQWDOOD SDVDUi D PRVWUDU HO QLYHO de humedad actual una vez que hayan pasado 5 segundos Presionar el botón Delay Retraso exhi...

Page 17: ...e la bolsa con cinta adhesiva en el interior de la tapa del cubo de agua 2 Coloque con cuidado el deshumidificador en la parte delantera o trasera 3 Siguiendo las flechas en la base deslice las 4 ruedas en su lugar 4 Coloque la unidad en posición vertical y espere 1 hora antes de usarla Instrucciones de instalación El deshumidificador está en su frente INSTRUCCIONES DE OPERACIÓN ...

Page 18: ...mente para aplicaciones residenciales GH LQWHULRU 1R GHEH XVDUVH SDUD DSOLFDFLRQHV FRPHUFLDOHV ni industriales Ŷ Coloque el deshumedificador en un piso firme y nivelado que sea lo suficientemente fuerte para soportar la unidad cuando la cubeta esté llena de agua Ŷ HMH SRU OR PHQRV SXOJDGDV GH HVSDFLR OLEUH DOUHGHGRU de la unidad para que exista una buena circulación de aire Ŷ Coloque el deshumedif...

Page 19: ...da 6DTXH HO WDQTXH GHO IUHQWH GH OD XQLGDG 2 Abra la tapa de drenaje sobre el lado de 3 Enrosque una manguera para jardín no provista en la boquilla cut to length y diríjala al drenaje de piso 9XHOYD D FRORFDU HO WDQTXH HQ OD XQLGDG NOTA El tanque debe estar en su lugar y bien sujeto para que el deshumedificador funcione Siempre cerciórese de que la tanque de agua esté asegurada en su lugar dentro...

Page 20: ...VLQ el filtro debido a que la suciedad y las pelusas lo obstruirán y reducirán su rendimiento Rejilla y gabinete Para limpiar el gabinete 8VH DJXD XQ GHWHUJHQWH GH EDMD FRQFHQWUDFLyQ 1R XVH blanqueador ni limpiadores abrasivos Para limpiar la rejilla superior o trasera 8VH XQD DVSLUDGRUD FRQ DFFHVRULR GH FHSLOOR VXDYH o un cepillo de mano Tanque de agua Para limpiar Después de algunas semanas limp...

Page 21: ...QVWRS SDUD obtener una máxima deshumidificación Las puertas y ventanas no están cerradas completamente Revise que todas las puertas ventanas y otras aberturas están cerradas completamente El secador de ropa podría estar generando aire húmedo en el recinto Instale el deshumedificador lejos de la secadora de ropa El secador debe desechar el aire hacia el exterior La temperatura del recinto está dema...

Page 22: ...sulte el esquema específico en la unidad 3DUD PRGHORV G GREEN BL BLUE BR BROWN B BLACK Y YELLOW W WHITE R RED NOTE THE PART MAY NOT BE USED 1 BECAUSE OF DIFFERENT COMPRESSOR 1 C M 1 R 0R BL M G Y G K4 3 4 FAN CAPACITOR B HERM C W R S B W BL B BR COMPRESSOR PROTECTOR HEAT main board TRANSFORMER UI board water full board wifi module ...

Page 23: ...XFWR FRPR UHVXOWDGR GH PRGLILFDFLRQHV VREUH el mismo o debido a un uso irrazonable incluyendo la falta de mantenimiento razonable o necesario Ŷ 5HHPSOD R GH IXVLEOHV GHO KRJDU R UHLQLFLR GH GLV XQWRUHV Ŷ DOODV FRPR FRQVHFXHQFLD GH FRUURVLyQ Ŷ DxRV RFDVLRQDGRV VREUH HO SURGXFWR SRU QLYHO GH suministro de voltaje inadecuado accidente incendio inundaciones o catástrofes naturales Ŷ DxRV FRQVHFXHQWHV ...

Page 24: ...e están disponibles mientras su JDUDQWtD D Q HVWi YLJHQWH D SXHGH DGTXLULU HQ FXDOTXLHU PRPHQWR D WUDYpV GH QWHUQHW RV 6HUYLFLRV GH SSOLDQFHV D Q HVWDUiQ DOOt FXDQGR VX JDUDQWtD FDGXTXH Q 88 GEAppliances com extended warranty R OODPH DO GXUDQWH el horario comercial habitual Conectividad Remota Para solicitar asistencia con la conectividad de red inalámbrica para modelos con activación remota visit...