background image

 

 

 

 

Page 1 of 16 

Drawing   : - TPC452 
Issue 

: - 2 

Date 

: - 23/05/16 

 
 
 
 
 
 
 

K100E 

DEHUMIDIFIER 

OWNER’S MANUAL

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.eipl.co.uk  

Summary of Contents for 10185GE-US

Page 1: ...Page 1 of 16 Drawing TPC452 Issue 2 Date 23 05 16 K100E DEHUMIDIFIER OWNER S MANUAL www eipl co uk ...

Page 2: ... 16 Drawing TPC452 Issue 2 Date 23 05 16 K100E PACKAGE CONTENTS Item Description Quantity 10185GE US Dehumidifier 1 off 3086144 Quick release hose coupling 1 off 3944110 PVC Tube 3 8 I D 7 8M TPC452 Manual 1 off ...

Page 3: ...m at a higher temperature but lower relative humidity than when the air entered the unit Continuous circulation of the room air through the dehumidifier unit gradually reduces the relative humidity in the room The K100E controls consist of an electronic humidity controller incorporating Bluetooth connectivity and Real Time Clock allowing the unit to interface with Android and IOS smart phones and ...

Page 4: ...range of temperature and humidity conditions A powerful and reliable reverse cycle defrost system controlled by an electronic timer guarantees positive de icing and thereby optimizing operation at low temperatures The unit incorporates a welded steel chassis and is finished in epoxy coated steel covers for resilience to damage caused by rough handling ...

Page 5: ... of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL 10185GE US HEIGHT 27 2 692mm WIDTH 22 8 580mm DEPTH 18 3 464mm WEIGHT 117 Lbs 53Kg AIRFLOW 300 CFM 510 M3 Hr POWER SUPPLY 110V 1Ph 60Hz POWER 1500 W max FINISH Epoxy coated steel REF...

Page 6: ... outlet grille of the dehumidifier unit must have clear space around them and not be obstructed in anyway WIRING Connect the power mains cable to a designated 30 Amp breaker As follows For Models without plugs Brown Live Blue Neutral Green Yellow Earth ground DRAINAGE The K100E has a water pump fitted as standard which is capable of discharging the condensate water 20ft vertical lift away from the...

Page 7: ...FF switch to ON C Check that the compressor is running D Leave the machine running for 15 minutes E Observe the evaporator coils through the rear upper grill to confirm frost operation i If the air temperature is below 80 F an even coating of frost should cover the entire evaporator coil ii If the air temperature is above 80 F frost and or droplets of condensed water should cover the entire evapor...

Page 8: ...water to a vertical height of 20ft Warnings Due to the high pressures within the refrigeration circuit under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved If the unit is switched off at the mains power supply for any re...

Page 9: ... LUBRICATING 3 To check the refrigerant charge run the unit for 20 minutes with humidistat set to maximum and briefly remove the cover The evaporator coil should be evenly frost coated across its surface At temperatures above 77 f the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas o...

Page 10: ... the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compressor fitted to the dehumidifier is a durable unit that should give many years of service Compressor failure can result from the machine losing...

Page 11: ... 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty Timer 2 Faulty bypass timer 1 Contact the Factory Service Center 2 Contact the Factory Service Center Unit vibrates excessively 1 Loose compressor mounts 2 Damaged fan 1 Tighten nuts on compressor mounts 2 Replace with a new fan W...

Page 12: ...9516 1 3 CAPILLIARY TUBE 047 2pcs 3014251 48 x2 4 COMPRESSOR R407c 3944915 1 5 CONDENSER COIL 3020727 1 6 EVAPORATOR COIL 3020732 1 7 DEFROST VALVE 3020833 1 8 FILTER DRYER 3020957 1 9 CONTACTOR 3930732 1 10 SOLENOID COIL 3030453 1 11 ROTARY SWITCH 3030557 1 12 MOTOR 3030126 1 13 CAPACITOR 3036337 1 14 USA PLUG 3934515 1 15 AXIAL FAN 3940002 1 16 PUMP 3160145 1 ...

Page 13: ... WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTION FOR YOUR RECORDS CLIP AND RETURN THIS CARD PLEASE NOTE WARRANTY REGISTRATION To ensure that your Ebac Dehumidifier is accorded the full coverage provided by this warranty please complete and mail this ...

Page 14: ...Page 14 of 16 Drawing TPC452 Issue 2 Date 23 05 16 ...

Page 15: ...Page 15 of 16 Drawing TPC452 Issue 2 Date 23 05 16 ...

Page 16: ...www eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www ebacusa com sales ebacusa com German Sales Office Ebac Industrial Products Ltd Gartenfelder Str 29 37 Gebäude 35 D 13599 Berlin Germany Tel 49 3043 557241 Fax 49 3043 557240 www eip ltd de sales eip ltd...

Reviews: