background image

www.pulsar.pl                                                      POE164864   

                         

GREEN POWER CCTV PoE

 

 

 

 

PSU features: 

 

 

supply output 16x0,4A/48V DC 

 

output voltage adjustment 

41V÷ 56V DC 

 

Wide range of supply voltage: 90

÷264V AC 

 

high efficiency: 90% 

 

16 outputs  protected with 0,5A fuses 

 

jumper selectable fuse type: fuse or polymer fuse

 

 

Vo

ltage control at the AUX1 ÷ AUX16 outputs 

 

designed for 10Mbit/s and 100Mbit/s  network 

 

LED optical indication 

 

 

FPS technical output 

– indication of the 

output fuse activation 

– relay and OC type 

 

protections: 

 

SCP short-circuit protection 

 

OVP overvoltage protection 

 

Surge protection 

 

Antisabotage protection 

 

OLP overload protection 

  Mounting plate for mounting the network 

switch - Ethernet Switch / Hub  

  warranty 

– 2 year from the production date 

 

TABLE OF CONTENTS: 
1. Technical description. 

1.1. General description 
1.2. Block diagram 
1.3. Description of components and connectors of the PSU 
1.4. Technical parameters 

2. Installation. 

2.1. Requirements 
2.2. Installation procedure 

3. Power supply operation indication. 

3.1. Optical indication 
3.2. Technical outputs 

4. Service and operation. 

4.1. Overload or short-circuit of the power supply output 

 

4.2. Maintenance 

 
 
1.  Technical description. 
 

1.1.  General description. 

 

The PSU is designed for supply of up to 16 webcams requiring stabilized voltage of 

48V DC.

The output voltage can 

be adjusted with a potentiometer between 

41V÷56V DC

. There are 16 power supply outputs, independently protected 

by melting fuses or PTC polymer fuses. Failure (short circuit)  in the  output circuit  will activate the melting fuse or 
PTC  fuse  and  disconnect  the  circuit  from  DC  power  (+  U).  Fuse  failure  is  indicated  by  switching  off  the 
corresponding  LEDs:  L1  for  AUX1, etc.  In addition, the  FPS  output (hi-Z  state)  and  LFPS  LED  are  activated  and 
the  relay  contacts  change  their  position.  The  PSU  is  housed  in  a  metal  enclosure  with  signaling  panel  equipped 
with  a  microswitch  indicating  door  opening  (front  cover).  The  power  is  carried  over  the  spare  pairs  (4/5

 

&  7/8), 

which, according to the Ethernet network standard, are not used for data transmission (data transmission uses 1/2 
and 3/6 data pairs). 

 

The PSU can not be used in Gigabit Ethernet networks, where all twisted pairs are involved in the 

transmission of data!  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for POE164864

Page 1: ...POE164864 v 1 0 PoE 48V 16x0 4A Switch mode power supply unit for CCTV EN Edition 1 from 01 12 2014 Supersedes the edition GREEN POWER CCTV PoE...

Page 2: ...ation 3 2 Technical outputs 4 Service and operation 4 1 Overload or short circuit of the power supply output 4 2 Maintenance 1 Technical description 1 1 General description The PSU is designed for sup...

Page 3: ...uses in the AUX1 AUX16 F 500mA circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L16 voltage indication at the AUX outputs during normal operation these LEDs are on 6 Network...

Page 4: ...www pulsar pl POE164864 GREEN POWER CCTV PoE 4 Fig 2 Components arrangement...

Page 5: ...tion of the power supply output voltage 5 PoE module 6 Plate for mounting the network switch Ethernet switch hub 7 TAMPER microswitch contacts of antisabotage protection NC Tab 2 Components of the PSU...

Page 6: ...wires 35cm Notes The enclosure has a 15mm distance from the mounting surface so the cables can be led PSU cooling fan cooling Safety of use Table 5 Protection class PN EN 60950 1 2007 I first Protect...

Page 7: ...ore installation cut off the voltage in the 230V power supply circuit 2 Mount the PSU in a selected location and lead the connecting cables 3 If required mount the switch network Ethernet Switch Hub o...

Page 8: ...cal indication The PSU has 16 LED lights at the front panel RED LED on DC voltage at the output of the switch mode PSU off no DC voltage at the output of the switch mode PSU RED LED on fuse failure at...

Page 9: ...pening volt free contact input indicating the status of the power supply doors PSU closed contacts closed NC PSU open contacts open NO 4 Service and operation 4 1 Overload or short circuit of the powe...

Page 10: ...here are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out a...