www.pulsar.pl POE164864
GREEN POWER CCTV PoE
6
The adjustment range of the output voltage
41÷56V DC
Output current
16 x 0,4 A
Ripple voltage
240 mV p-p max.
Short-circuit protection SCP
PoE MODULE
16 x F 0,5A or 16 x PTC 0,5A (jumper selectable)
PSU MODULE
105% ÷ 135% of PSU power, electronic current limiting
Overload protection OLP
105% ÷ 135% of PSU power, electronic current limiting
Overvoltage protection OVP
58÷68V DC
Surge protection
16 x varistor
Antisabotage protection:
- TAMPER output indicating enclosure opening
- microswitch, NC contacts (enclosure closed),
0,5A@50V DC (max.)
Optical indication of operation:
YES
– LED lights
Technical outputs:
- FPS technical output indicating output fuse
activation
- OC type, 50mA max.
Normal operation: L state (0V),
failure: H state (hi-Z), (automatic return once the normal
operation is restored)
- relay type: 1A@ 30VDC/50VAC
F1 ÷ F16 fuses
F 0,5A or PTC 0,5A
Mechanical parameters (Table 4).
Enclosure dimensions
291 x 387 x 101+15 (WxHxD) [mm] (+/-2)
Mounting
See Fig. 3
Net weight
4,90kg / 5,30kg
Enclosure
DC01 steel plate, 1,0mm, RAL 9003
Closing
Cylindrical screw x 2 (at the front) lock assembly possible
Terminals
Switch mode power supply:
Φ0,63-2,05 (AWG 22-12)
PoE module: Φ0,5-2,05 (AWG 24-12)
IN1 ÷ IN16 inputs: RJ45 8P8C, shielded
AUX1 ÷ AUX16 outputs: RJ45 8P8C, shielded
TAMPER output:
wires 35cm
Notes
The enclosure has a 15mm distance from the mounting surface so the cables can
be led. PSU cooling: fan cooling
Safety of use (Table 5).
Protection class PN-EN 60950-1:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Insulation electrical strength:
- between input (network) circuit and the output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
1
00 MΩ, 500V/DC
Operation parameters (Table 6).
Operating temperature
-
10ºC...+40ºC (see Figure1)
Storing temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, no condensation
Vibrations during operation
unacceptable
Surges during operation
unacceptable
Direct insolation
unacceptable
Vibrations and surges during transport
According to the PN-83/T-42106 standard
2. Installation.
2.1. Requirements.
The buffer PSU should be mounted by a qualified installer, holding relevant permits and licenses
(applicable and required for a given country) for 230V/AC and low-voltage installations. The unit should be
mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative humidity
(RH=90% maximum, no condensation) and temperature range from -
10°C up to +40°C. The power supply should
operate in a vertical position in order to provide free and convectional air flow through ventilating holes of the
enclosure.