background image

www.pulsar.pl                                                      POE084824B   

GREEN POWER CCTV PoE

 

 

 

 

2.2. Installation procedure. 

1. Before installation, cut off the voltage in the 230V power-supply circuit. 

2. Mount the PSU in a selected location and lead the connecting cables.  
3. If required, mount the switch network (Ethernet Switch / Hub) on the mounting plate (element 6, Figure 3) using cable 
ties supplied with the PSU. An example of mounting the Ethernet switch is shown in Figure 4: 

 

 

 

Figure 4. An example of mounting the Ethernet switch. 

 

4.  Connect  the  power  cables  (230V  AC)  to  L-N  terminals  of  the  PSU.  Connect  the ground  wire  to  the  terminal  marked 

with grounding symbol:

. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. 

The power cables should be connected to the appropriate terminals on the connection board through the bushing.  

 

 

The shock protection circuit shall be done with a particular care: the yellow and green wire 

coat of  the  power  cable  should be connected to  the  terminal  marked  with  the  

  symbol  

in  the  PSU enclosure. Operation of the PSU without the properly made and fully operational 
shock  protection  circuit  is  UNACCEPTABLE!  It  can  cause  damage  to  the  equipment  or  an 
electric shock

 

 
5. Connect the network cables (Ethernet) to the PoE module: supply voltage is present only at the AUX sockets and the 
cameras should be connected to them. Pin assignment of the AUX and IN sockets is shown in the Figure 5: 
 

 

 

Fig. 5. Connection of cameras and network devices to the IN and AUX terminals. 

 
 
 

6. 

Use  the  F1/PTC1  ÷  F8/PTC8  jumpers  to  select  the  type  of  short  circuit  /  overload  protection  of  individual  circuits. 

Jumper in the Fx position 

– melting fuse activation, PTCx – PTC fuse activation. 

7. If needed, the following technical connections can be made: 
- FPS technical output of the PSU status 

– indicates the voltage loss at any of the outputs (AUX1 ÷ AUX8). 

TAMPER

 indicating enclosure opening. 

8. Check the power supply output voltage: 
- output voltage of the unloaded power supply without a battery should amount to U=54V DC. 
9. Connect the batteries in series according to the color markings: 
- battery output (+V): BAT+ cable/ red 

Summary of Contents for GREEN POWER CCTV POE084824B

Page 1: ...POE084824B v 1 0 PoE 54V 8x0 3A 4x7Ah PoE buffer power supply for up to 8 IP camera EN Edition 4 from 25 05 2015 Supersedes the edition 3 from 15 05 2014 GREEN POWER CCTV PoE...

Page 2: ...D optical indication protections SCP short circuit protection OVP overvoltage protection Surge protection Antisabotage protection OLP overload protection Mounting plate for mounting the network switch...

Page 3: ...et network standard are not used for data transmission data transmission uses 1 2 and 3 6 data pairs The PSU can not be used in Gigabit Ethernet networks where all twisted pairs are involved in the tr...

Page 4: ...ble 1 The description of components of the PoE module Fig 2 Components arrangement Fig 3 The view of the PSU Component No Fig 3 Description 1 The module of the switch mode PSU 2 LED light indicating c...

Page 5: ...c current limiting Battery circuit protection SCP and reverse polarity connection melting fuse Overvoltage protection OVP 62 1 72 9V DC Deep discharge battery protection UVP U 37 V 5 disconnecting the...

Page 6: ...vironmental class with normal relative humidity RH 90 maximum no condensation and temperature range from 10 C up to 40 C The power supply should operate in a vertical position in order to provide free...

Page 7: ...nnected to the terminal marked with the symbol in the PSU enclosure Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE It can cause damage to...

Page 8: ...LED Fig 2 component 1 indicates DC voltage at the PoE module input During normal operation DC supply the LED is permanently illuminated No DC no DC voltage at the module input is indicated by turning...

Page 9: ...If the PTC polymer fuses are used disconnect the load from the power supply output for approximately 1 minute to restore output voltage the time needed to cool down the PTC fuse In case of melting fus...

Page 10: ...service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...

Reviews: