Operation, Calibration & Service Manual
LinkBelt - DS350 1334 Console
CALIBRATION MODE
If the calibration is not stored in memory, the system will automatically enter calibration mode with the
first screen below. To enter the calibration mode from the operating screen press “INFO” (10) and
then “CTRL” (11) buttons. The system will then give you the option to zero the force transducer or
enter the calibration mode. Refer to 9.3 CALIBRATION ZERO SETTINGS to zero the procedure.
NOTE: After the calibration mode has been started, to return to the operating screen or restart
calibration press “SEL” button. All screens must be completed and acknowledged before the
calibration will be saved to memory.
Use the appropriate section to guide you through the calibration:
9.4. 1. main boom calibration
9.4.2. jib calibration
9.4.3. main boom and jib calibration
The following screen is a sample of a calibration screen and description of the values shown.
Radius: the distance from the centerline of rotation to the hook block. Remember to add the
distance from the centerline of rotation to the point on the upper or lower frame from which
measurements are taken.