Operation, Calibration & Service Manual
LinkBelt - DS350 1334 Console
Button and Control Light “Alarm Stop”
This ALARM STOP BUTTON (6) allows the audible alarm to be silenced for
approximately 15 seconds by pressing this button. Reference
“Audible
Alarm” (12).
Button and Control Light “Tare”
The button “TARE” (7) is used to indicate the “Net load” on the LC Display
(1). Net load is the present load, less lifting tackle and hook block. The Tare
Button (7) has to be activated
before
lifting.
After pushing the “Tare Button” (7) the load display is set to zero (taring)
and the control light lights up. After lifting a load the display shows the
net
load
(pay load).
The
net load
display will change to the actual load display when the boom
radius is changed (either by angle or length).
B utton "LIMITS"
Button to start the function "program limit values".
For the proceeding please refer to
chapter 5.1.