77
Unscrew the two screws from the
auger holder
(3)
using a Torx T30
end piece. Finally, remove the
auger by pulling it out of the
furnace
(4)
. It is possible that some
residue remains in the auger tube
making it more difficult to remove.
If this is the case, turn the auger
clockwise to release it.
11.5 EXHAUST BLOWER REPLACEMENT
To replace the exhaust blower, remove the right panel of the furnace’s jacket. Remove the flue collar
(A)
by
unscrewing it completely. Unscrew the three screws and nuts holding the exhaust blower and pull the blower
towards you to remove it.