![PSG Dover Mouvex B200 Flow Control Original Instructions Manual Download Page 12](http://html1.mh-extra.com/html/psg-dover/mouvex-b200-flow-control/mouvex-b200-flow-control_original-instructions-manual_1622702012.webp)
12/22
NT 1401-X00 10 18 B200 Flow Control e
Reversing the rotation direction requires that the com-
pressor be returned to the factory.
Speed pick-up on the male screw :
Table 1
Male screw and drive shaft speed correspondence
Speed pick-up on the female screw :
Table 2
Female screw and drive shaft speed correspondence
3.2 B200 PS with drive shaft
3.2.1 Installation of the compressor
• Mount the compressor in a position where it is protec-
ted from dirt, debris and road spray. The mounting
location should allow for regular inspection, cleaning
and maintenance.
• The B200 compressor mounting points are located on
the sides of the body.
Installation is performed by means of screws, minimum
grade 8.8.
3.2.2 Recommended drive conditions
The drive shaft must be sized so as to be able to accept
the loads above and also the starting torque.
Operating torque at full speed
It is the responsibility of the installer to check that his
design protects the transmission if the compressor blocks.
Compressors B200 12R PS and B200 10L PS must
be protected by a 400 Nm torque limiter, in order to
protect the truck's transmission if the compressor is
jammed. MOUVEX may not be held liable for any
damages resulting from such jamming if the torque
limiter has not been installed.
Comply strictly with the following instructions :
• The drive shaft slides perfectly well during rotation.
Square slip joints are forbidden.
• Drive shaft length should be as short as possible and
the drive shaft MUST be balanced.
Direction of rotation
Fixation points
Female
screw
Male screw
Inlet shaft speed
(rpm)
Female screw speed
(rpm)
B200 12R
850
11 600
1 000
13 640
1 100
15 000
1 200
16 365
B200 10L
700
11 450
800
13 095
900
14 730
1 000
16 365
Inlet shaft speed
(rpm)
Male screw speed
(rpm)
B200 12R
850
13 910
1 000
16 365
1 100
18 000
1 200
19 640
B200 10L
700
13 750
800
15 710
900
17 675
1 000
19 640
B200
Pressure
1,5 bar
2,0 bar
2,5 bar
Torque 12R
(Nm)
83
93
103
Torque 10L
(Nm)
100
111
124
WARNING
DRIVES SHAFTS MUST BE GUARDED
IF EXPOSED. OPERATION WITHOUT
GUARDS CAN CAUSE SERIOUS PER-
SONAL INJURY, MAJOR PROPERTY
DAMAGE OR DEATH.
Do not operate
without guard
in place.
3. INSTALLATION (continued)