background image

 

 

 

Item 1: Actuator flange 
Item 2: Adapter for valve spindle

 

7. Valve mounting 

The PSQ-E actuators are provided with a mechanical interface according to ISO 5211 for valve mounting. 
The gear does contain an internal octagon SW22 to connect the actuator to the valve shaft. 
 

Figure 5: Actuator flange 

 

Check if the actuator flange suits the valve flange 

 

If required, use standard adapters to adapt to the 
valve shaft 

 

Clean the surface of the connection components, 
lubricate valve shaft slightly 

 

Position the actuator on the valve 

 

Tighten the screws in a diagonal sequence according 
to the required torque 

  
For valve mounting please ensure that the 
cover of the actuator is always closed in order 
to avoid that components inside the actuator 
are damaged. 

 

8. Setting of the mechanical stop 

There are two adjustable screws installed for setting the mechanical limit of the angular travel. 

 

 

When setting the mechanical end positions, only the handwheel may be used. Do not 
operate the actuator electrically. 

 
 

 

Remove the protection cap (, item 3) from either stop screw. 

 

Unscrew both stop screws anti-clockwise by approximately 5 turns. 

 

Move the actuator to the closed position by turning the handwheel clockwise.  

 

Turn the stop screw for closed position (, item 1) to the stop. 

 

Move the actuator to the open position by turning the handwheel anti-clockwise.  

 

Turn the stop screw for open position (, item 2) finger tight. 

 

Screw on the protection cap onto the stop screw. 

Figure 6: Mechanical stop 

 
Item 1: Stop screw CLOSED position 
Item 2:  Stop screw OPEN position 
Item 3:  Protecting caps 

 
① 

 
② 

① 
 

② 

③ 

③ 

Summary of Contents for PSQ-E Series

Page 1: ...Operating Instructions PSQ E Version 2019 01 08 2019 PS Automation GmbH...

Page 2: ...internal limit switches 8 9 2 Setting of the additional position switches 9 10 Electric supply 9 10 1 Wiring diagram 10 11 Commissioning 10 12 Service Maintenance 10 12 1 Cleaning 10 12 2 Spare Parts...

Page 3: ...ication This may cause danger to life and limb of the user or a third party damage the actuator and other property belonging to the owner reduce safety and function of the actuator To prevent such pro...

Page 4: ...ried out on the actuators are excluded from the manufacturer s liability Supply voltage may only be switched on after the proper closure of the main cover or terminal box 3 Storage For appropriate sto...

Page 5: ...r torque is transmitted via a spur gear onto the sun wheel of a Wolfrom gear The rotating output wheel of the Wolfrom gear holds a removable drive bush to connect the actuator with the valve stem Two...

Page 6: ...clutching or declutching Figure 4 Manual operation Do not exceed the adjusted electrical stroke limits by using the hand wheel The mechanical stop must be set accordingly to protect the valve If you...

Page 7: ...osed in order to avoid that components inside the actuator are damaged 8 Setting of the mechanical stop There are two adjustable screws installed for setting the mechanical limit of the angular travel...

Page 8: ...ternal limit switches Ensure that the mains supply is secured against accidental switching on The limit switches are pre adjusted in the factory An additional adjustment of the two lower switching cam...

Page 9: ...ition and repeat the adjustment if necessary 10 Electric supply Switch mains off before starting to work Connect acc to wiring diagram on the main frame The mains supply cords must be suitably dimensi...

Page 10: ...into an intermediate stroke position using the hand wheel Switch the setting signal briefly between OPEN and CLOSE and ensure that the actuator operates in the correct direction If necessary reverse t...