background image

 

 

 

1. Symbols and safety 

Danger signs 

The following danger signs are used in this operating manual: 
 

Caution! There is a general risk of damage related to health and/or properties.  
 
 
 
Danger! Electrical voltages are present that may lead to death. Life threatening risks 
may occur due to electrical voltages! Avoid personal or material damages by 
observing applicable regulations and safety standards! 

 
Other notes 

 

The motor surface temperature may rise when maintaining, inspecting and repairing the actuator 
immediately after the operation. There is a danger of burning the skin! 

 

Always consult the relevant operating instructions when mounting PS accessories or operating the 
actuator with PS accessories. 

 

Connections for signal in- and output are double isolated from circuits that can be under dangerous 
voltage. 

 

General dangers of non-compliance with safety regulations 

PSQ-E actuators are built at state-of the art technology and are safe to operate. Despite of this, the 
actuators may be hazardous if operated by personnel that has not been sufficiently trained or at least 
instructed, and if the actuators are handled improperly, or not used as per specification. 
This may 

 

cause danger to life and limb of the user or a third party,  

 

damage the actuator and other property belonging to the owner, 

 

reduce safety and function of the actuator. 

 
To prevent such problems, please ensure that these operating instructions and the safety regulations in 
particular have been read and understood by all personnel involved in the installation, commissioning, 
operation, maintenance and repair of the actuators. 

 
Basic safety notes 

 

The actuators may only be operated by skilled and authorized operating personnel. 

 

Make sure to follow all security advices mentioned in this manual, any national rules for accident 
prevention, as well as the owner´s instructions for work, operation and safety. 

 

The isolating procedures specified in these Operating Instructions must be followed for all work 
pertaining to the installation, commissioning, operation, change of operating conditions and modes, 
maintenance, inspection, repair and installation of accessories 

 

Before opening the actuator cover, ensure that mains supply is isolated and prevented from unintended 
re-connection. 

 

Areas that can be under voltage have to be isolated before working on them. 

 

Ensure that the actuators are always operated in faultless condition. Any damage or faults, and changes 
in the operational characteristics that may affect safety, must be reported at once. 

 

 

Summary of Contents for PSQ-E Series

Page 1: ...Operating Instructions PSQ E Version 2019 01 08 2019 PS Automation GmbH...

Page 2: ...internal limit switches 8 9 2 Setting of the additional position switches 9 10 Electric supply 9 10 1 Wiring diagram 10 11 Commissioning 10 12 Service Maintenance 10 12 1 Cleaning 10 12 2 Spare Parts...

Page 3: ...ication This may cause danger to life and limb of the user or a third party damage the actuator and other property belonging to the owner reduce safety and function of the actuator To prevent such pro...

Page 4: ...ried out on the actuators are excluded from the manufacturer s liability Supply voltage may only be switched on after the proper closure of the main cover or terminal box 3 Storage For appropriate sto...

Page 5: ...r torque is transmitted via a spur gear onto the sun wheel of a Wolfrom gear The rotating output wheel of the Wolfrom gear holds a removable drive bush to connect the actuator with the valve stem Two...

Page 6: ...clutching or declutching Figure 4 Manual operation Do not exceed the adjusted electrical stroke limits by using the hand wheel The mechanical stop must be set accordingly to protect the valve If you...

Page 7: ...osed in order to avoid that components inside the actuator are damaged 8 Setting of the mechanical stop There are two adjustable screws installed for setting the mechanical limit of the angular travel...

Page 8: ...ternal limit switches Ensure that the mains supply is secured against accidental switching on The limit switches are pre adjusted in the factory An additional adjustment of the two lower switching cam...

Page 9: ...ition and repeat the adjustment if necessary 10 Electric supply Switch mains off before starting to work Connect acc to wiring diagram on the main frame The mains supply cords must be suitably dimensi...

Page 10: ...into an intermediate stroke position using the hand wheel Switch the setting signal briefly between OPEN and CLOSE and ensure that the actuator operates in the correct direction If necessary reverse t...

Page 11: ...r works in Bad Duerkheim Germany or to our representatives for evaluation of failures and repair 13 Appendix 13 1 Accessories Various options are available in order to adapt the actuators to the vario...

Page 12: ...12 13 2 Declaration of Incorporation of Part Completed Machinery and EC Declaration of Conformity in compliance with the Directives on EMC and Low Voltage...

Page 13: ...Sytc HK Super net www maxonicauto com India PS Automation India Pvt Ltd Srv No 25 1 Narhe Industrial Area A P Narhegaon Tal Haveli Dist IND 411041 Pune Phone 91 20 25 47 39 66 Fax 91 20 25 47 39 66 E...

Reviews: