6
3. Storage
For appropriate storage, the following instructions have to be met
:
•
Only store the actuators in ventilated, dry rooms.
•
Store the actuators on shelves, wooden boards, etc., to protect them from soil moisture.
•
Cover the actuators with plastic foil to protect them from dust and dirt.
•
Protect the actuators against mechanical damage.
4. Betriebsbedingungen und Einbaulage
•
PSF-M-EX actuators may be operated at ambient temperatures according to the technical data sheet.
•
Operating modes correspond to IEC 60034-1, 8: S2 for short cycle and S4 for modulating operation (actuator-
specific values see actuator-specific data sheets).
•
For protection against moisture and dust, the enclosure rating is IP65 according to EN 60529.
•
When installing the actuators, leave enough space to allow cover removal (Fig.1).
•
The actuator can be installed vertically or horizontally or any position in between. The actuator must not be
installed with the cover pointing downwards (Fig.2).
Figure 1: Installation dimensions