6
5 Menu structure
5.1 "Info" menu
The following measured values are displayed automatic in the Info menu:
Display
e.g.
Meaning
Can be reset
75 °C
Displays current collector temperature
No
52 °C
Displays current storage tank temperature
No
5.4 "Basic Setup" menu
The hydraulic diagrams and additional functions are displayed in the Basic Setup
menu. Settings must only be changed by a specialised technician.
Display
e.g.
Meaning
Value range Factory
setting
Current
setting
max
65 °C
Storage tank:
Maximum permissible tempe-
rature
15 – 95°C
60°C
dT max
7 K
Storage tank:
Switch-on difference
3 – 40K
10K
dT min
3 K
Storage tank:
Switch-off difference
2 – 35K
5K
Tmin
Absolute treshold - Minimum
temperature at which temp.
difference is analysed
5..90
10°C
on
Manually switching on / off the
switching output A1 (pump 1)
0 = off
1 = on
0
RES
Reset the values to the factory
setting
V1.1
Software release
Menü „Info“
Settings and changes in
this menu must only be
carried out by a specialised
technician. Incorrect settings can
damage or adversely affect the
function of the solar power system.