1  Application area / device features

1.1 Application area

The Sunny Scout 1328 controllers are high-performance microprocessor-controlled 

units for controlling the functions of solar thermal systems. The Sunny Scout 1328 

controls solar power systems equipped with one collector and one storage tank. 
The controllers are designed for use in dry rooms as well as residential, business 

and commercial applications. Prior to commissioning the device, make sure to 

verify that the intended use complies with the applicable regulations. 

1.2 Device features

The Sunny Scout 1328 controller is equipped with the following features:

Operating menu with graphic symbols

 

Automatic display of the temperature values

 

No manual operation needed

 

Extensive functions for system monitoring that display symbols to indicate er-

 

rors and faults. Additionaly LED indicators.
Storage of all values even during a prolonged mains power supply outage

 

Various protective functions, such as system protection, collector protection, 

 

anti-freeze and flow monitoring

Available accessories:

Temperature sensor PT1000

 

Sensor connection box

 

Immersion sleeves

 

2  Safety instructions

Always completely disconnect the device from the operating voltage before 

 

performing installation or wiring work on the electrical equipment. 

Never mix up the connections of the protective low voltage areas (sensors) with 

the 230V connections. Otherwise, the device will be destroyed. The device and 

the connected sensors may carry deadly voltages.
Solar power systems can reach high temperatures. Such temperatures pose a 

 

risk of burns! Exercise caution when installing the temperature sensors!
Mount the Sunny Scout 1328 controller in a position where it will not be sub�ect-

Sunny Scout 1328 controller in a position where it will not be sub�ect-

 controller in a position where it will not be sub�ect-

 

ed to excessive operating temperatures (> 50°C) by any external heat sources.

For safety reasons, the system may only remain in manual operation for testing 

purposes. In this operating mode, the system does not monitor for maximum 

temperatures and sensor functions. If there is any recognisable damage to the 

controller, cables or the connected pumps and valves, the system must not be 

started. 

 

 

 

 

 

 

 

 

 

 

All installation and wiring 
work must only be carried 

out on the controller when the 
device is disconnected from the 
power supply. 
The Sunny Scout 1328 must only 
be connected and commissioned 
by qualified personnel. In doing 
so, the applicable safety regulati-
ons must be observed.

Summary of Contents for Sunny Scout 1328

Page 1: ...Microcontroller controlled temperature difference controller for solar thermal systems Operatingmanual Sunny Scout 1328...

Page 2: ...7 1 2 Thermostat 8 7 1 3 RPM control 8 7 2 Protective functions 8 7 2 1 Anti freeze protection Jumper on 8 7 2 3 System protection 8 7 2 3 Pump blocking protection 8 8 System monitoring 9 8 1 Sensor...

Page 3: ...onnection box Immersion sleeves 2 Safety instructions Always completely disconnect the device from the operating voltage before performing installation or wiring work on the electrical equipment Never...

Page 4: ...nductor terminals N are electrically connected and are not switched The switching output A1 is electronic 230V N O contact If potential free contacts are required the appropriate corresponding accesso...

Page 5: ...side of the housing using a suitable tool Briefly pressing the button switches the controller from the Info menu to the Basic Setup menu Here you can scroll through and select the variables and infor...

Page 6: ...nge Factory setting Current setting max 65 C Storage tank Maximum permissible tempe rature 15 95 C 60 C dT max 7 K Storage tank Switch on difference 3 40K 10K dT min 3 K Storage tank Switch off differ...

Page 7: ...Mains phase N Neutral conductor mains and outputs A1 Solar circuit pump switching output 1 Sensor connections S1 Collector sensor S2 Lower storage tank Switch positions Temp diff controller all off H...

Page 8: ...he output A1 can be operated using an RPM control Minimum 30 7 2 Protective functions The controller is equipped with the following protective functions 7 2 1 Anti freeze protection This function must...

Page 9: ...s that are automatically detected by the controller and therefore can be displayed using error messages Faults that the controller cannot detect 9 1 Faults with error messages LED s Display Meaning Me...

Page 10: ...230V compo nents for short circuits Defect device Contact the supplier Output is not switched on Switch on condition is not fulfilled Wait until switch on condition is satisfied Pump symbol rotates b...

Page 11: ...cording to EN 60730 DIN VDE 0631 IEC 60664 IEC Output Voltage Power switching output 230V 1A approx 230VAfor cos 0 7 1 0 Fuse protection Fine wire fuse 5 x 20mm 2A T 2 amperes delayed action fuse Misc...

Page 12: ...itory action reduction of price is excluded Warranty claims may only be submitted by the customer and are non transferable If a defect occurs during the warranty period please contact the supplier ins...

Reviews: