10  Specifications

Housing

Material

100% recyclable ABS housing for wall mount-

ing

Dimensions W x H x D in mm, 

weight

95 x 75 x 50;  

approx. 130 g

Protection class

IP20 according to DIN 40050, IEC 529, VDE 

0470, EN 60529

Electrical specifications

Operating voltage

AC 230 Volts, 50Hz, -10 – +15%

Radio interference level 

N according to VDE 0875

Max. cable cross-section  

230V connections 

2.5 mm² fine-wire/single wire

Temperature sensor   

measuring range

PT1000, 1 kΩ at 0°C 

-30°C .. +250°C

Rated impulse voltage 

4 kV according to EN 60730/DIN, VDE 0631, IEC 

60664/IEC

Output Voltage 

Power - switching output

230V~ 

1A / approx. 230VAfor cos φ = 0,7-1,0 

Fuse protection

Fine-wire fuse 5 x 20mm, 2A/T  

(2 amperes, delayed-action fuse) 

Miscellaneous

Operating temperature

0  – 50°C

Storage temperature

-10  – +65°C

Humidity

max. 60 %

11  Resistance table PT1000

The temperature sensors can be checked for proper function using the following 

temperature resistance table and an ohmmeter:

Temperature  

in °C

Resistance  

in Ohm

Temperature  

in °C

Resistance  

in Ohm

-30

882

60

1232

-20

921

70

1271

-10

960

80

1309

0

1000

90

1347

10

1039

100

1385

20

1077

120

1461

30

1116

140

1535

40

1155

200

1758

50

1194

 

Subject to change in 
accordance with technical 

advances!

Summary of Contents for Sunny Scout 1328

Page 1: ...Microcontroller controlled temperature difference controller for solar thermal systems Operatingmanual Sunny Scout 1328...

Page 2: ...7 1 2 Thermostat 8 7 1 3 RPM control 8 7 2 Protective functions 8 7 2 1 Anti freeze protection Jumper on 8 7 2 3 System protection 8 7 2 3 Pump blocking protection 8 8 System monitoring 9 8 1 Sensor...

Page 3: ...onnection box Immersion sleeves 2 Safety instructions Always completely disconnect the device from the operating voltage before performing installation or wiring work on the electrical equipment Never...

Page 4: ...nductor terminals N are electrically connected and are not switched The switching output A1 is electronic 230V N O contact If potential free contacts are required the appropriate corresponding accesso...

Page 5: ...side of the housing using a suitable tool Briefly pressing the button switches the controller from the Info menu to the Basic Setup menu Here you can scroll through and select the variables and infor...

Page 6: ...nge Factory setting Current setting max 65 C Storage tank Maximum permissible tempe rature 15 95 C 60 C dT max 7 K Storage tank Switch on difference 3 40K 10K dT min 3 K Storage tank Switch off differ...

Page 7: ...Mains phase N Neutral conductor mains and outputs A1 Solar circuit pump switching output 1 Sensor connections S1 Collector sensor S2 Lower storage tank Switch positions Temp diff controller all off H...

Page 8: ...he output A1 can be operated using an RPM control Minimum 30 7 2 Protective functions The controller is equipped with the following protective functions 7 2 1 Anti freeze protection This function must...

Page 9: ...s that are automatically detected by the controller and therefore can be displayed using error messages Faults that the controller cannot detect 9 1 Faults with error messages LED s Display Meaning Me...

Page 10: ...230V compo nents for short circuits Defect device Contact the supplier Output is not switched on Switch on condition is not fulfilled Wait until switch on condition is satisfied Pump symbol rotates b...

Page 11: ...cording to EN 60730 DIN VDE 0631 IEC 60664 IEC Output Voltage Power switching output 230V 1A approx 230VAfor cos 0 7 1 0 Fuse protection Fine wire fuse 5 x 20mm 2A T 2 amperes delayed action fuse Misc...

Page 12: ...itory action reduction of price is excluded Warranty claims may only be submitted by the customer and are non transferable If a defect occurs during the warranty period please contact the supplier ins...

Reviews: