12  Warranty conditions

The Sunny Scout 1328 controllers are carefully produced and tested on an auto-

Sunny Scout 1328 controllers are carefully produced and tested on an auto-

 controllers are carefully produced and tested on an auto-

matic testing station. If any failures occur, first check if there are any operation / 

setting or system errors. Furthermore, check the pump and temperature sensor 

connections.
PROZEDA GmbH provides a 2-year warranty starting at the date of purchase and 

according to the following conditions.
a)    The warranty comes into effect if the purchased good exhibits a material or 

quality defect. If the defect is caused by improper handling, by exceeding the 

permitted values stated in the specifications, improper wiring, invalid technical 

modifications to the device performed by the buyer or by an another company 

other than PROZEDA GmbH, the warranty shall be void.

b)    The warranty requires a written notice that describes the defect in detail as well 

as a copy of the customer invoice. 

PROZEDA GmbH can choose to fulfil the guarantee, at its own discretion, by one 

of the following measures 

- Repair (reconditioning) or 

- Delivery of a fully functional replacement product 

The device shall be repaired within 1 month after PROZEDA GmbH has received 

it.  

If the device is not repaired within the two repairs attempts, the buyer is enti-

tled to delivery of a fully functional replacement product. 

If a replacement product is delivered, a new warranty that corresponds to these 

conditions shall come into effect.

c)    Any further warranty (redhibitory action, reduction of price) is excluded.
Warranty claims may only be submitted by the customer and are non-transferable.
If a defect occurs during the warranty period, please contact the supplier / installer. 

When returning the device for warranty service, please make sure to send a descrip-

tion of the error and, if possible, the system diagram along with the wiring diagram.
 

13  Declaration of conformity

We, Prozeda GmbH, declare under our sole responsibility that the Sunny Scout type 

1328 product complies with the following standards:
DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 

of 15 12.2004 on the approximation of the laws of the Member States relating to 

electromagnetic compatibility and repealing Directive 89/336/EEC 
Law on the electromagnetic compatibility of equipment (EMC) of 26 February 2008 
DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 

12 December 2006 on the approximation of the laws of the Member States con-

cerning electrical equipment for use within certain voltage limits 
DIN EN 61326-1, VDE 0843-20-1:2006-10 Electrical measurement, control and labo-

ratory use - EMC requirements - Part 1: General requirements (IEC 61326-1:2005); 

German version EN 61326 -1:2006 
DIN EN 61326-2-2, VDE 0843-20-2-2:2006-10 Electrical measurement, control and 

laboratory use - EMC requirements - Part 2-2: Particular requirements - Test, operat-

ing conditions and performance requirements for portable test, measurement and 

monitoring equipment for use in low voltage power supply systems (IEC 61326-2-

2:2005); German version EN 61326-2-2:2006

Operating manual for Sunny Scout 1328 

04/2009

Summary of Contents for Sunny Scout 1328

Page 1: ...Microcontroller controlled temperature difference controller for solar thermal systems Operatingmanual Sunny Scout 1328...

Page 2: ...7 1 2 Thermostat 8 7 1 3 RPM control 8 7 2 Protective functions 8 7 2 1 Anti freeze protection Jumper on 8 7 2 3 System protection 8 7 2 3 Pump blocking protection 8 8 System monitoring 9 8 1 Sensor...

Page 3: ...onnection box Immersion sleeves 2 Safety instructions Always completely disconnect the device from the operating voltage before performing installation or wiring work on the electrical equipment Never...

Page 4: ...nductor terminals N are electrically connected and are not switched The switching output A1 is electronic 230V N O contact If potential free contacts are required the appropriate corresponding accesso...

Page 5: ...side of the housing using a suitable tool Briefly pressing the button switches the controller from the Info menu to the Basic Setup menu Here you can scroll through and select the variables and infor...

Page 6: ...nge Factory setting Current setting max 65 C Storage tank Maximum permissible tempe rature 15 95 C 60 C dT max 7 K Storage tank Switch on difference 3 40K 10K dT min 3 K Storage tank Switch off differ...

Page 7: ...Mains phase N Neutral conductor mains and outputs A1 Solar circuit pump switching output 1 Sensor connections S1 Collector sensor S2 Lower storage tank Switch positions Temp diff controller all off H...

Page 8: ...he output A1 can be operated using an RPM control Minimum 30 7 2 Protective functions The controller is equipped with the following protective functions 7 2 1 Anti freeze protection This function must...

Page 9: ...s that are automatically detected by the controller and therefore can be displayed using error messages Faults that the controller cannot detect 9 1 Faults with error messages LED s Display Meaning Me...

Page 10: ...230V compo nents for short circuits Defect device Contact the supplier Output is not switched on Switch on condition is not fulfilled Wait until switch on condition is satisfied Pump symbol rotates b...

Page 11: ...cording to EN 60730 DIN VDE 0631 IEC 60664 IEC Output Voltage Power switching output 230V 1A approx 230VAfor cos 0 7 1 0 Fuse protection Fine wire fuse 5 x 20mm 2A T 2 amperes delayed action fuse Misc...

Page 12: ...itory action reduction of price is excluded Warranty claims may only be submitted by the customer and are non transferable If a defect occurs during the warranty period please contact the supplier ins...