background image

User Manual 

sens07vest

 

Page 6 

 

May 2020 

1.3

 

sens07 inflator components 

 

The 

sens07inflator

 consists of 4 components: 

1.

 

The inflator head contains the electronics, the sensors, the 
red/green light indicators, the battery, the optical light sensor 
to configure sens07 by using any smartphone and the self-test 
button. 

2.

 

The actuator module gives the thrust to pierce the CO

2

 cylinder 

and opens the gas flow in order to inflate the rescue bladder. 
The actuator module needs to be replaced after every inflation. 

3.

 

The base unit connects the sens07 head, actuator module and 
CO

2

 cylinder to the inflatable bladder. The base unit is equipped 

with the manual emergency handle which allows manual infla-
tion of the bladder at any time. 

4.

 

CO

2

 cylinder (60gr. or 95gr.) with 1/2-inch thread providing the 

needed gas volume to inflate the bladders up to 50 meter 
depth. It is important to verify that a fresh and unused CO

2

 cyl-

inder is inserted before each dive. 

 

 

User Manual 

sens07vest 

May 2020 

 

Page 7 

1.4

 

Activation on water contact 

The 

sens07

 

inflator

 immediately 

starts its auto-supervision when wa-
ter can be “sensed” by the integrated 
contact-free water sensors. When 
taking out of the water, the sens07 
inflator automatically goes into a 
power-saving “ready” mode. 
The sens07 inflator deliberately has no "power" button - it is al-
ways switched on, even if it is stored for months or years; activa-
tion cannot be forgotten.  
However, it is possible to enable manual deactivation of the 

sens07 

inflator

 for security reason like in aircrafts. 

Please note that switching off the sens07 inflator doesn’t save en-
ergy and is not recommended by ProVitaTec. 

1.5

 

No battery to change or replace 

Battery change or battery charge is not required 
during the lifetime of the sens07 inflator due to 
ultra-low energy consumption. The life-time of a 
sens07 inflator is at least 5 years, the full life-
time depending on user activity. 
In the unlikely event that battery power should run low due to very 
extensive usage, the red LED will light up when pressing the self-
test button. 

 

 

Summary of Contents for sens07vest

Page 1: ...User Manual sens07vest May 2020 Page 1 User Manual Mai 2020...

Page 2: ...Inflation reason report 15 3 2 2 Red LED Battery low 15 4 sens07 app 16 4 1 Introduction 16 4 2 Installation and registration 17 4 3 Tab 1 Profiles 18 4 3 1 Profiles configurator basic 19 4 3 2 Profil...

Page 3: ...r after the dive in order to prevent inflation of the bladder The sens07vest is designed to protect free divers and spear fisher up to 50 meters under water when using a 95gr CO2 cylinder Be low this...

Page 4: ...nserted before each dive User Manual sens07vest May 2020 Page 7 1 4 Activation on water contact The sens07 inflator immediately starts its auto supervision when wa ter can be sensed by the integrated...

Page 5: ...p User Manual sens07vest May 2020 Page 9 1 8 Customization using the sens07 app The inflation parameters and features called profile can be customized using the sens07 app and are wirelessly transferr...

Page 6: ...ns07vest May 2020 Page 11 2 2 Suspend upcoming inflation while diving Pressing the self test button when the sens07vest is submerged will suspend freeze the risk inflation countdown for the specified...

Page 7: ...Perform the self test as described after replacing the actuator module User Manual sens07vest May 2020 Page 13 3 LED signals The inflator head has 2 front LED for important information and 3 back LED...

Page 8: ...self test button Blackout warning Inflation occurred sens07 inflator is functional Timed inflation active Timed inflation standby User Manual sens07vest May 2020 Page 15 3 2 System LEDs on the back s...

Page 9: ...charge available for IOS and for Android devices and can be downloaded and installed in the usual way from the Apple App store or Android Play store A registration code for private or cooperate users...

Page 10: ...basic The drowning algorithm is based on 3 depth zones Safe zone Diving zone and Inflation zone A simple inflation countdown starts at the specified value when entering into the Div ing Zone Inflatio...

Page 11: ...eing at least 10 seconds in the Diving Zone Upcoming inflation can only be stopped by pressing the button Combat diver can disable the LED Signal un der water for this specific profile The last segmen...

Page 12: ...support if activated 3 After transfer check for the blinking green LED confirming suc cessful data transfer 4 Confirm seeing the green LEDs by clicking Yes on the app 5 Click on Retry in case of no b...

Page 13: ...d seconds until inflation There are 3 sliders for additional options The countdown start after transfer or on first water contact Countdown aborts when sens07 is taken out of the water Countdown abort...

Page 14: ...Bladder Verify the bladder for any hole or other kind of dam age It is recommended to inflate the bladder every 2 years to check it for holes Straps Verify if the straps are well sewed and the buckle...

Page 15: ...e that the manual cord is accessible from outside and that the cord runs directly without any diversion to the sens07 base The cord is equipped with a Velcro tag near to the red handle This Velcro tag...

Page 16: ...ne starts IC Remaining in safe zone resets IC Entering diving zone starts IC Expired IC inflates sens07vest 0 min 1 min Basic Configuration Mode Safe zone 3 m Inflation countdown 2 min Diving zone 20...

Page 17: ...m Blackout countdown 15 sec Diving zone 20 m 15 m Warning zone Blackout 15 sec User Manual sens07vest May 2020 Page 33 7 Advanced explanations trouble shooting 7 1 Unsuccessful optical data transfer A...

Page 18: ...uration of the inflator head can be tested without the vest CO2 cylinder base unit and actuator module Just immerse the inflator head into water and observe the LED for water zone indicator and inflat...